Abstract
Compressive imaging(CI)can offer a versatile improvements for imaging systems, such as smaller compressed data volume and super-resolution. Among various methods to realize Compressive imaging, pushing encoding mask has attracted the most attention with its compatibility to the space remote sensing. However, complex pre- calibrations are usually needed for calibrating the encoding mask to achieve the measurement matrix for the image reconstruction. Herein, we design a pushing compressive imaging system which fixed with the function of situ calibration of the encoding mask. The pushing compressive imaging system was constructed, and the experimental results confirmed that the system had the ability for data compression and super-resolution. And above all, the system can avoid the complex pre-calibration, which makes the on-orbit calibration feasible. In the simulations, twice, three times and four times resolutions higher than the captured image’s resolution are performed respectively, which confirm that the method can improve the target image resolution based on the relative low resolution raw captured target images. Furthermore, by pushing the mask precisely which can be considered equivalent to the real pushing imaging, we have reconstructed the true super-resolution target image accurately based on the mask calibration and 6 captured pushing imaging frames.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lei Wang, Zhengzheng Shao, Jiying Liu, Qianwen Nie, Hui Jia, Suian Dai, Xiaofeng Wang, Jubo Zhu, and Xiujian Li "A push-broom compressive imaging system with situ calibration function for encoding mask", Proc. SPIE 10255, Selected Papers of the Chinese Society for Optical Engineering Conferences held October and November 2016, 1025508 (8 March 2017); https://doi.org/10.1117/12.2267747
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Imaging systems

Compressive imaging

Computer programming

Image resolution

Super resolution

Image restoration

RELATED CONTENT


Back to Top