The high-power diode-laser industry is dependent on highly qualified production output for fast axis collimation (FAC)
lenses in scalable quantities. Not only controlled production processes but also the optical qualification of the final FAC
product contribute to this goal. The product qualification approach chosen is based on diode laser collimation by active
alignment and automated positioning of the FAC in collimation for the fast axis and imaging in the slow axis, allowing
to evaluate the collimation performance with a specific and installed diode laser on individual emitter intensity profiles.
We present the automated setup with results for corresponding sensitivity and repeatability analysis for the measurement
of residual divergence.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
M. Forrer, V. Lendenmann, B. Rusconi, P. Wüst, H. Forrer, A. Kunz, H. Moser, "Collimation performance measurement of FAC lenses by active and automated alignment," Proc. SPIE 11667, Components and Packaging for Laser Systems VII, 1166705 (5 March 2021); https://doi.org/10.1117/12.2579175