Paper
18 March 1994 Practical applications in UV Raman line imaging of water vapor
Peter A. DeBarber, Cecil F. Hess, Robert W. Pitz, Sastri P. Nandula, Thomas M. Brown III, P. Annette Skaggs
Author Affiliations +
Abstract
High-temperature water vapor imaging based on Raman scattering for hypersonic exhaust diagnostics has been developed. A temperature-independent UV Raman line imaging instrument that is calibrated with room air and readily scaled to large combustion facilities has been tested in a laboratory H2/air combustor. The H2O concentration measurements exhibit a single-shot standard deviation of approximately 8%. In this paper we investigate practical issues concerning the application of UV Raman line imaging for quantitative water vapor measurements.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peter A. DeBarber, Cecil F. Hess, Robert W. Pitz, Sastri P. Nandula, Thomas M. Brown III, and P. Annette Skaggs "Practical applications in UV Raman line imaging of water vapor", Proc. SPIE 2122, Laser Applications in Combustion and Combustion Diagnostics II, (18 March 1994); https://doi.org/10.1117/12.171303