Paper
27 April 1999 High-accuracy development monitoring technology
Shinichi Ito, Kei Hayasaki, Kenji Kawano, Koutaro Sho, Shoji Mimotogi, Fumio Komatsu, Katsuya Okumura
Author Affiliations +
Abstract
A development monitor system capable of highly accurate control of pattern width has been established. This system is composed of a unique monitor pattern on the process wafer, the 0th order diffraction light measuring unit, and the image analysis and process control unit. In the conventional development process in which no monitor system is employed, the CD variation in 200nm line width was about 15nm when +/- 5 percent dose error exist. However, using the new system, 1nm of CD variation was obtained. In this article, a high-sensitivity monitor pattern is proposed and its performance in controlling 200nm line and space patterns in the development process is reported.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shinichi Ito, Kei Hayasaki, Kenji Kawano, Koutaro Sho, Shoji Mimotogi, Fumio Komatsu, and Katsuya Okumura "High-accuracy development monitoring technology", Proc. SPIE 3743, In-Line Characterization, Yield Reliability, and Failure Analyses in Microelectronic Manufacturing, (27 April 1999); https://doi.org/10.1117/12.346907
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Semiconducting wafers

Process control

Image processing

Critical dimension metrology

CCD cameras

Control systems

Deep ultraviolet

Back to Top