Paper
24 September 2010 Aging study in advanced photomasks: impact of EFM effects on lithographic performance with MoSi binary and 6% attenuated PSM masks
Author Affiliations +
Abstract
As mask dimensions continue to shrink to meet the ITRS roadmap and with the extension of 193 nm immersion lithography, the masks are affected by electromagnetic field at high NA. Absorber degradation is regularly reported under long term 193 nm exposures in the subwavelength diffraction regime. The damage mechanism known as Electric Field induced Migration of chrome (EFM) partly contributes to the lifetime reduction of advanced masks. The EFM results in a progressive alteration of the Critical Dimension (CD), CD uniformity (CDU) degradation and assist features. This study evaluates the impact and the rate of absorber degradation due to an intensive ArF irradiation on assist features and its influence on the through pitch process window for sub-45 nm technology nodes. Lithographic performance is characterized after cumulative reticle aging stages. The aging test exposures are carried out directly on 193 nm scanner to duplicate the production environment. The analysis of printed wafers is correlated to advanced mask inspection (AIMSTM). This paper reports results on irradiation damage sensitivity on two types of reticles: conventional 6% attenuated PSM and new binary material OMOG (Opaque MoSi On Glass) reticle. Test patterns have been generated with and without a set of Optical Proximity Corrections (OPC) model calibration structures based on 45nm down to 28nm half-pitch design. The combination of metrology measurements used in this work between printed wafers and reticles enables to define accurately the impact of mask damage caused by EFM effects on various test patterns and CD evolution and highlight some trends about advances masks aging phenomenon.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
I. Servin, J. Belledent, M. O. Fialeyre, B. Connolly, M. Lamantia, M. Sczyrba, M. K. Jullian, B. Le Gratiet, and L. Pain "Aging study in advanced photomasks: impact of EFM effects on lithographic performance with MoSi binary and 6% attenuated PSM masks", Proc. SPIE 7823, Photomask Technology 2010, 78230N (24 September 2010); https://doi.org/10.1117/12.864529
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photomasks

Critical dimension metrology

Semiconducting wafers

Reticles

Binary data

Scanning electron microscopy

Scanners

RELATED CONTENT

Characterization of linewidth variation on 248 and 193 nm...
Proceedings of SPIE (September 14 2001)
Mask specification for for wafer process optimization
Proceedings of SPIE (October 20 2006)
Aerial image measuring system at 193 nm a tool...
Proceedings of SPIE (December 06 2004)
Some challenges for mask making to keep up with the...
Proceedings of SPIE (December 18 1998)
CD-SEM suitability for CD metrology of modern photomasks
Proceedings of SPIE (August 25 1999)
Full field imaging with a 157-nm scanner
Proceedings of SPIE (May 28 2004)

Back to Top