Paper
27 August 2015 Negative temporal cross covariance in SrI2:Eu
Author Affiliations +
Abstract
Scintillation light is widely believed to be Poisson or super-Poisson. We tested this hypothesis by measuring the temporal correlation between two detectors detecting scintillation light resulting from the same gamma-ray event in SrI2:Eu . Poisson light is expected to yield zero temporal correlations, while super-Poisson light is expected to yield positive, and sub-Poisson light is expected to yield negative temporal correlation. Scintillation light in SrI2:Eu was found to be negatively correlated. Therefore, we conclude that the scintillation light in SrI2:Eu is sub-Poisson.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vaibhav Bora, David Fastje, Harrison H. Barrett, Eric Clarkson, Lars Furenlid, Kanai S. Shah, and Urmila Shirwadkar "Negative temporal cross covariance in SrI2:Eu", Proc. SPIE 9595, Radiation Detectors: Systems and Applications XVI, 959504 (27 August 2015); https://doi.org/10.1117/12.2214406