Open Access
1 January 2008 Matrix-assisted pulsed laser evaporation of poly(D,L-lactide) for biomedical applications: effect of near infrared radiation
Valeria Califano, Francesco Bloisi, Luciano Rosario Maria Vicari, Oana Bretcanu, Aldo R. Boccaccini
Author Affiliations +
Abstract
The deposition of thin films of poly(D,L-lactide) (PDLLA) by using the matrix-assisted pulsed laser evaporation (MAPLE) technique is investigated. PDLLA is a highly biocompatible and biodegradable polymer, with wide applicability in the biomedical field. The laser wavelength used in the MAPLE process is optimized to obtain a good-quality deposition. The structure of the polymer film is analyzed by Fourier transform infrared spectroscopy (FTIR). It is found that the chemical structure of PDLLA undergoes little or no damage during deposition with near-infrared laser radiation (1064 nm). It is thus confirmed that at this wavelength, the MAPLE technique can be applied for fragile biopolymer molecules, which are easily damaged by other laser radiations (UV radiation). This method allows future development of tailored polymer coatings for biomedical applications.

1.

Introduction

Synthetic polyesters, such as polylactides and polyglycolides and their copolymers, have found a wide range of applications in the biomedical field thanks to their biocompatibility and biodegradability.1, 2 In particular, polylactides, derived from lactic acid, degrade in the human body via a hydrolytic reaction. This reaction produces first oligomers and then lactic acids, of which the L-lactic acid is a natural intermediate in carbohydrate metabolism. The monomer unit of polylactide, shown in Fig. 1 , includes a chiral carbon. The mechanical properties of such a polymer depend on its stereoregularity. Optically pure poly(L-lactide) (PLLA) and poly(D-lactide) (PDLA) are semicrystalline materials, while poly(D,L-lactide) (PDLLA), consisting of racemic lactate units, is amorphous. Although the mechanical properties of PLLA and PDLA are superior with respect to PDLLA, those polymers are brittle at room temperature.3 Moreover, the degree of crystallinity of polylactides influences their degradation rate in biological fluids, i.e., amorphous PDLLA exhibits the highest degradation rate. Due to its relative high rate of degradation, and the absence of late foreign body reactions due to crystalline remnants,4 PDLLA has been extensively studied for in-vivo biomedical applications, such as osteosynthesis temporary implant materials4 and composite scaffolds,5 controlled release of drugs,6 proteins and antigens,7 resorbable sutures,8 and lately as coating for improving mechanical properties of brittle bioactive glass scaffolds for bone tissue engineering.9

Fig. 1

Molecular structure of poly(D,L-lactide).

014028_1_009801jbo1.jpg

For some of these current or potential applications, in particular for drug delivery systems and biomedical coatings, a reliable technique for depositing biopolymer films, which allows a careful control of their thickness and structure, would be highly beneficial.

Recently, a new technique has been developed which is particularly well suited for polymer thin film deposition. The matrix-assisted pulsed laser evaporation (MAPLE) technique was first developed at the U.S. Naval Research Laboratory,10 inspired by the pulsed laser deposition (PLD) technique. In PLD, a solid target of the material is ablated by a pulsed laser beam and the ablated material deposits onto a nearby substrate, forming a film. PLD is largely used for inorganic thin film deposition,11, 12 although some addition polymers13, 14 have been also successfully deposited. However, the ablation of addition polymers seems to proceed via a chain scission, ablation of oligomers, and repolymerization. This is clearly not possible in general for condensation polymers or other organic molecules.

Contrary to PLD, in MAPLE the target is not the bulk material itself, but a frozen solution of the molecules to be deposited in a highly volatile and light-absorbing solvent. When the laser impacts the target, a plume is formed. The mechanism of ablation is still under study, but it is thought that this highly nonlinear process proceeds through a photochemical or phototermal process15, 16 that produces phase explosion;17, 18 as the solvent evaporates, the polymer molecules attain sufficient kinetic energy through collisions with the evaporating solvent molecules to be transferred into the gas phase.

The plume is composed by the volatile solvent molecules and the bigger polymer solute molecules. The volatile solvent molecules are pumped away by a vacuum pump, while the heavier polymer molecules deposit onto the substrate. This technique is particularly well suited for biopolymers: in MAPLE, most of the laser radiation is absorbed by the solvent, thus hindering the photochemical damage that a direct irradiation of these fragile macromolecules is likely to produce.

The MAPLE technique allows accurate control of film thickness by varying several parameters, such as the concentration of the target solution, the laser power, and the deposition time.

For the deposition of biopolymer thin films, the MAPLE technique is a suitable alternative to solution-based processing techniques due to the following facts.

  • 1. The MAPLE is a noncontact deposition technique, thus eliminating a major source of contamination, i.e., the solvent and its impurities, and it can be integrated with other sterile processes.

  • 2. The accurate thickness control is beneficial to tailor the in-vivo degradation rate of PDLLA, being the time of degradation proportional to the thickness of the film.

  • 3. The MAPLE technique allows multiple-layer depositions without the risk of redissolving the first deposited layer. This characteristic offers interesting perspectives for multilayer deposition of composite coatings.

Many biopolymers have already been successfully deposited by MAPLE, 19, 20, 21, 22 including PDLLA for drug delivery system applications.23

This work deals with preliminary experiments for PDLLA thin film deposition by the MAPLE technique, with the ultimate objective of developing optimal coatings for biomedical applications. The main difference with the PDLLA thin films already obtained is the laser wavelength used in this investigation. Until now, following PLD trends, only UV laser light or resonant infrared (RIR)24 laser light, in which the laser radiation is resonant with some vibrational mode of the molecule to deposit, have been utilized. The use of a different laser radiation, as near-infrared, resonant with the solvent rather than with the molecule to deposit, can be beneficial for biopolymer deposition because of pronounced decomposition of the polymer molecules induced by UV light25 and the necessity of low absorption from the polymer. The possibility of ablating a frozen target and depositing a thin film with this wavelength radiation has been already explored by our research group.26, 27

For a successful MAPLE deposition, a strongly light absorbing matrix should be used in combination with low absorption by the guest material. Furthermore, the solvent and concentration should be selected so that the guest material can dissolve to form a dilute, particulate-free solution. These requirements are usually difficult to fulfil completely. In our experiments, the laser wavelength of 1064nm was chosen to minimize the damage to the polymer, which can be damaged by UV radiation. Chloroform was chosen as the solvent, since on one hand it is able to dissolve the polymer forming a clear solution, and on the other hand it can absorb the laser radiation because it has an absorption band, albeit weak, between 1050 and 1080nm .28

The use of 1064-nm laser radiation should favor the deposition of the intact polymer, because the mechanism of ablation is thought to be substantially different than that observed with UV light:16 in the latter, single or multiphoton absorption leads to electronic transitions that can cause photofragmentation. In the former, anharmonic vibrational modes are excited, generating the thermal energy required for vaporization.

2.

Experimental

2.1.

Materials

PDLLA (purasorb PDL) of inherent viscosity 1.92dlg was purchased from Purac Biochem (Gorinchem, The Netherlands). CHCl3 (purchased from Sigma-Aldrich) of > 99% purity was used as solvent.

Two sets of solutions of PDLLA in CHCl3 were prepared, one set containing 0.5wt% of PDLLA and the other set containing 2wt% , by pouring the solvent on the weighted polymer and allowing it to dissolve for two hours. Manual stirring was not possible to dissolve the polymer, because of the high viscosity of the solvated polymer flakes.

2.2.

Matrix-Assisted Pulsed Laser Evaporation Procedure

Our MAPLE deposition system, depicted in Fig. 2 , consisted of a cylindrical vacuum deposition chamber. The target holder was a copper cup of about 2-ml capacity. It was fitted with a 2-D computer-controlled movement system, allowing the full scan of a rectangular area to avoid overheating and drilling. The target cup was in thermal contact with a liquid nitrogen tank, and the target (PDLLA in CHCl3 ) was frozen in situ. The substrate holder, holding a KBr pellet for allowing Fourier Transform Infrared (FTIR) analysis, was placed parallel to the target surface at a maximum distance of 11cm . Before filling the liquid nitrogen tank, the deposition chamber was closed and filled with helium to remove atmospheric moisture. The target temperature was then reduced up to 103K . After the solidification of the target, the helium flux was stopped and the pressure reduced up to 105Pa . The laser was then started and the substrate brought at the minimum distance position (1cm) from the target. During this procedure, about 1500 laser pulses impacted the target, ablating possible impurities or residual moisture on the surface.

Fig. 2

MAPLE setup, top view. The target movement is in the yz plane, where the z -axis is normal to the xy plane.

014028_1_009801jbo2.jpg

The laser was a common Q-switched Nd:YAG laser connected to the chamber by means of an articulated arm and passing through an optical window. The laser was operated at three different wavelengths: 1064nm (fundamental harmonic), 532nm (second harmonic), and 355nm (third harmonic). The laser pulse duration was 7ns with a repetition rate of 10Hz . The laser spot on the target, which was elliptical because of the 45-deg laser incident angle, was 0.32cm2 for 1064-nm, 0.41cm2 for 532-nm, and 0.030cm2 for 355-nm laser wavelength. The laser fluence was varied between 213 and 1140mJcm2 .

The films obtained, together with the deposition parameter details and the solution concentration, are reported in Table 1 .

Table 1

Laser wavelength (λ) , fluence (F), number of pulses, concentration, and visible features of the MAPLE-deposited PDLLA films.

Sample λ (nm) F(mJ∕cm2) nr pulsesConcentration wt%Film
PDLLA1106499065,0000.5Visible
PDLLA2532213120,0000.5Not visible
PDLLA335547063,0000.5Not visible
PDLLA41064114060,0002Visible
PDLLA51064811120,0002Visible
PDLLA6532270120,0002Not visible
PDLLA7532270180,0002Not visible

2.3.

Characterization

To detect possible modification of the monomer unit chemical structure of PDLLA, FTIR spectroscopy analysis was carried out. FTIR spectroscopy allows the determination of a short to medium range structure of a material, thus giving information essentially on the repeat unit of a polymer. FTIR absorption spectra of the films deposited on KBr pellets were recorded, in the 4000 to 400cm1 range, using a spectrometer equipped with a deuterated triglycine sulphate with potassium bromide windows (DTGS KBr ) detector. A spectral resolution of 2cm1 was chosen. The spectrum for each sample represents an average of 64 scans, which were corrected for the spectrum of the blank KBr pellet.

The microstructure of the samples was analyzed by using a LEO Gemini field emission gun scanning electron microscope (SEM), coupled with energy dispersive spectroscopy (EDS). Samples were chromium sputtered and observed at an accelerating voltage of 20kV .

3.

Results and Discussion

With both sets of solutions (see Table 1), a visible film formed only using 1064-nm laser radiation. This is not surprising for 532-nm radiation, since PDLLA and CHCl3 are both optically transparent and do not absorb green light. On the other hand, the 355-nm radiation is not efficiently absorbed by CHCl3 , which presents its maximum UV absorption around 245nm and only 0.003 times this value at 280nm , as specified by the supplier. On the contrary, chloroform presents an absorption band in its NIR absorption spectrum centred at around 1064nm .28

FTIR spectra of the three visible films (PDLLA1, PDLLA4, and PDLLA5) are shown in Fig. 3a in the 4000 to 400cm1 range. The spectrum of a film obtained by casting a drop of solution on a KBr pellet is also shown for comparison. The FTIR spectra of all the other samples did not show any peak emerging from the baseline and are not reported.

Fig. 3

(a) FTIR spectra between 4000 and 400cm1 of drop cast PDLLA (trace a), PDLLA5 (trace b), PDLLA4 (trace c), and PDLLA1 (trace d). (b) FTIR spectra of drop cast PDLLA (trace a) and PDLLA5 (trace b) between 2000 and 1000cm1 .

014028_1_009801jbo3.jpg

The spectra of PDLLA5 and drop cast films are normalized for the maximum intensity band at 1756cm1 to make them comparable in terms of band intensities. Furthermore, a baseline was subtracted from each spectrum.

From the spectra in Fig. 3a, it is possible to observe that all the bands of PDLLA5 film coincide in position and relative intensity with the bands of the drop cast film, and no new bands due to decomposition appear. This means that little or no chemical modification with respect to the bulk polymer occurred during MAPLE deposition with the 1064-nm wavelength and 811-mJcm2 laser radiation. PDLLA4, obtained with higher laser fluence but a smaller pulse number, shows only a very weak peak at 1756cm1 and no bands are detectable for the PDLLA1 sample, obtained at higher fluence and a lower pulse number and solution concentration, though the film is visible.

In Fig. 3b, the spectra of drop cast PDLLA and PDLLA5 are reported alone in a smaller wavenumber range (2000 to 1000cm1 ) to show the precise correspondence of all the bands in terms of wavenumber. The spectra are normalized as before, but no baseline was subtracted. To show the intensity match between the two spectra, for each spectrum the integrated peak area of each peak was calculated and divided by the peak area of the 1756-cm1 band. The results are reported in Table 2 , together with the band assignments.29 The peak areas were calculated by integrating between the onset and the offset of each peak.

Table 2

Peak position, intensity (VS: very strong, S: strong, M: medium, W: weak, VW: very weak), and band assignment of PDLLA. Integrated areas ratio: A0 = integrated area of the 1756-cm−1 FTIR band of the drop cast PDLLA film; Ai = integrated area of the i th FTIR peak of the drop cast PDLLA film; A0′ = integrated area of the 1756-cm−1 FTIR band of PDLL5; and Ai′ = integrated area of the i th FTIR peak of PDLL5.

Peak positionIBand assignment Ai∕A0 Ai′∕A0′
2985W C-H asym. stretch of - CH3 0.040.033
2940W C-H sym. stretch of - CH3 0.0250.016
1880VW CH stretch of - CH --
1756VS C=O stretch11
1454M CH3 asym. bend0.140.14
1385M CH3 sym. bend0.130.12
1362 C-H bend of - CH + CH3 sym. bend
1272W C-O-C stretch + CH bend0.0760.086
1188S C-O-C asym. stretch + CH3 asym. rocking0.410.34
1133M CH3 asym. rocking0.10.094
1090S C-O-C sym. stretch0.290.22
1048W C-CH3 stretch0.0540.037
862VW C-COO stretch--
753VW C=O bend--

In spite of the inaccuracy of the method, especially in establishing the precise point of onset and offset of the peaks, the match between the peak relative intensities is surprisingly good.

It is then demonstrated that with 1064-nm radiation, the chemical structure of the biopolymer monomer unit underwent little or no modification. As shown in the literature,23 good results were obtained for MAPLE deposition of PDLLA deposited with 193-nm radiation; the films giving FTIR spectra were well correlated with that of the drop cast PDLLA. However, some mismatch between the spectra was present, in terms of relative intensity of the low wavenumber bands. It must be pointed out that FTIR spectroscopy is a short-medium range technique, and it does not allow for determining whether the polymer remained intact in its molecular weight as well.

Figure 4 shows SEM images of PDLLA1 [Figs. 4a and 4b], PDLLA4 [Figs. 4c and 4d], and PDLLA5 [Figs. 4e and 4f] coatings at low and high magnifications. For PDLLA1, and PDLLA4, the substrate (KBr) features are visible. KBr pellets are formed by grains with roughness of 100 to 200nm on the grain and about 1μm on the grain border, as determined by atomic force microscopy (AFM) (not shown).

Fig. 4

SEM images of PDLLA deposits at different magnifications: (a) and (b) PDLLA1, (c) and (d) PDLLA4, (e) and (f) PDLLA5.

014028_1_009801jbo4.jpg

For sample PDLLA1, obtained at a lower concentration of the target, it is seen that no film was formed. This is in accordance with FTIR measurements, which show no specific band for this sample. Only a few aggregates of the polymer film can be seen on the substrate. On the contrary, sample PDLLA4 (higher concentration and laser fluence) is seen to be almost homogeneously coated by the polymer, which forms aggregates of a few microns in size. The KBr grain borders are still visible, indicating a film thickness of less than 1μm . Finally, sample PDLLA5 appears homogeneously deposited on the substrate, forming aggregates of 1 to 10μm . The KBr grain borders are completely hidden under the polymer coating. PDLLA5 coatings were obtained at the same target concentration used for PDLLA4, at lower laser fluence but using a double-pulse number. The more homogenous and thicker coating obtained is therefore related to the higher pulse number. It should be noted that the formation of polymer aggregates by MAPLE deposition has been already observed for polyethylene glycol (PEG),30 another biotechnologically important polymer. MAPLE-deposited PEG showed aggregates of 5 to 10μm in diameter, and it was demonstrated that, although it is possible that particles were transferred individually, the morphology of the film depended on the substrate temperature.31 They concluded that uniform films of PEG could not be easily obtained by MAPLE, compared with high quality film produced by other methods.

Obtaining a rough surface formed by polymer aggregates can be a drawback, in general, when trying to develop homogeneous films. In the present case, however, the presence of a given surface roughness can be an advantage due to the potential application of the film as coating for tissue engineering scaffolds. A rough surface exhibiting topographical features is considered to favor cell adhesion.32

4.

Conclusions

PDLLA thin films are successfully obtained by the MAPLE technique using a 1064-nm laser wavelength. We demonstrate that with this wavelength, it is possible to obtain better results than with UV radiation in the case of fragile biopolymer molecules, which are easily damaged for interaction with UV radiation. In particular, FTIR spectroscopy analysis is indicative of little or no damage of the chemical structure of the macromolecule’s monomer unit. The microscopic homogeneity and surface topography of the deposited PDLLA films are investigated by SEM.

References

1. 

A. J. Domb, J. Kost, and D. Wiseman, Handbook of Biodegradable Polymers, CRC Press, Boca Raton, FL (1998). Google Scholar

2. 

S. W. Shalaby and K. J. L. Burg, Absorbable and Biodegradable Polymers, CRC Press, Boca Raton, FL (2003). Google Scholar

3. 

J. R. Sarasua, A. L. Arraiza, P. Balerdi, and I. Maiza, “Crystallinity and mechanical properties of optically pure polylactides and their blends,” Polym. Eng. Sci., 45 745 –753 (2005). 0032-3888 Google Scholar

4. 

W. Heidemann, S. Jeschkeit, K. Ruffieux, J. H. Fischer, M. Wagner, G. Krüger, E. Wintermantel, and K. L. Gerlach, “Degradation of poly(D,L)lactide implants with or without addition of calciumphosphates in vivo,” Biomaterials, 22 2371 –2381 (2001). 0142-9612 Google Scholar

5. 

J. A. Roether, J. E. Gough, A. R. Boccaccini, L. L. Hench, V. Maquet, and R. Jérôme, “Novel bioresorbable and bioactive composite based on bioactive glass and polylactide foams for bone tissue engineering,” J. Mater. Sci.: Mater. Med., 13 1207 –1214 (2002). 0957-4530 Google Scholar

6. 

T. Chung, Y. Huang, and Y. Liu, “Effects of the rate of solvent evaporation on the characteristics of drug loaded PLLA and PDLLA microspheres,” Int. J. Pharm., 212 161 –169 (2001). 0378-5173 Google Scholar

7. 

R. Nakaoka, Y. Tabata, and Y. Ykada, “Enhanced antibody production through sustained antigen release from biodegradable granules,” J. Controlled Release, 37 215 –224 (1995). 0168-3659 Google Scholar

8. 

A. S. Karikari, W. F. Edwards, J. B. Mecham, and T. E. Long, “Influence of peripheral hydrogen bonding on the mechanical properties of photo-cross-linked star-shaped poly(D, L-lactide) networks,” Biomacromolecules, 6 2866 –2874 (2005). 1525-7797 Google Scholar

9. 

Q. Z. Chen and A. R. Boccaccini, “Poly(D,L-lactic acid) coated 45S5 Bioglass®-based scaffolds: processing and characterization,” J. Biomed. Mater. Res., 77A 445 –457 (2006). 0021-9304 Google Scholar

10. 

R. A. McGill and D. B. Chrisey, “Method of producing a film coating by matrix assisted pulsed laser deposition,” (2000) Google Scholar

11. 

D. B. Chrisey, J. S. Horwitz, and R. E. Leuchtner, “Excimer laser ablation of a YBa2Cu3O7δ target in a vacuum: characterization of the mass and energy of ejected material,” Thin Solid Films, 206 (1-2), 111 –115 (1991). https://doi.org/10.1016/0040-6090(91)90402-J 0040-6090 Google Scholar

12. 

D. H. Lowndes, D. B. Geohegan, A. A. Puretzky, D. P. Norton, and C. M. Rouleau, “Synthesis of novel thin-film materials by pulsed laser deposition,” Science, 273 898 –903 (1996). https://doi.org/10.1126/science.273.5277.898 0036-8075 Google Scholar

13. 

G. B. Blanchet and S. I. Shah, “Deposition of polytetrafluoroethylene films by laser ablation,” Appl. Phys. Lett., 62 (9), 1026 –1028 (1993). https://doi.org/10.1063/1.108514 0003-6951 Google Scholar

14. 

M. A. Stevens, B. A. Weir, G. J. Denton, and R. H. Friend, “Laser ablation of conjugated polymers,” Synth. Met., 101 234 –235 (1999). https://doi.org/10.1016/S0379-6779(98)01293-4 0379-6779 Google Scholar

15. 

D. B. Chrisey, A. Piqué, R. A. McGill, J. S. Horowitz, B. R. Ringeisen, D. M. Bubb, and P. K. Wu, “Laser deposition of polymer and biomaterial films,” Chem. Rev. (Washington, D.C.), 103 553 –576 (2003). https://doi.org/10.1021/cr010428w 0009-2665 Google Scholar

16. 

D. M. Bubb, S. L. Johnson, R. Belmont, K. E. Schriver, R. F. Haglund Jr., C. Antonacci, and L. S. Yeung, “Mode specific effects in resonant infrared ablation and deposition of polystirene,” Appl. Phys. A, 83 147 –151 (2006). https://doi.org/10.1007/s00339-005-3478-8 0947-8396 Google Scholar

17. 

L. V. Zhigilei, E. Leveugle, B. J. Garrison, Y. G. Yingling, and M. Zeifman, “Computer simulations of laser ablation of molecular substrates,” Chem. Rev. (Washington, D.C.), 103 321 –348 (2003). https://doi.org/10.1021/cr010459r 0009-2665 Google Scholar

18. 

T. E. Itina, L. V. Zhigilei, and B. J. Garrison, “Matrix assisted pulsed laser evaporation of polymeric materials: a molecular dynamics study,” Nucl. Instrum. Methods Phys. Res. B, 180 238 –244 (2001). https://doi.org/10.1016/S0168-583X(01)00423-2 0168-583X Google Scholar

19. 

R. Cristescu, D. Mihaiescu, G. Socol, I. Stamatin, I. N. Mihailescu, and D. B. Chrisey, “Deposition of biopolymer thin films by matrix assisted pulsed laser evaporation,” Appl. Phys. A, 79 1023 –1026 (2004). 0947-8396 Google Scholar

20. 

A. L. Mercado, C. E. Allmond, J. C. Hoekstra, and J. M. Fitz-Gerald, “Pulsed laser deposition vs. matrix assisted pulsed laser evaporation for growth of biodegradable polymer thin films,” Appl. Phys. A, 81 591 –599 (2005). https://doi.org/10.1007/s00339-004-2994-2 0947-8396 Google Scholar

21. 

R. Cristescu, G. Dorcioman, C. Ristoscu, E. Axente, S. Grigorescu, A. Moldovan, I. N. Mihailescu, T. Kocourek, M. Jelinek, M. Albulescu, T. Buruiana, D. Mihaiescu, I. Stamatin, and D. B. Chrisey, “Matrix assisted pulsed laser evaporation processing of triacetate-pullulan polysaccharide thin films for drug delivery systems,” Appl. Surf. Sci., 252 4647 –4651 (2006). 0169-4332 Google Scholar

22. 

R. Cristescu, T. Kocourek, A. Moldovan, L. Stamatin, D. Mihaiescu, M. Jelinek, I. Stamatin, I. N. Mihailescu, and D. B. Chrisey, “Laser deposition of cryoglobulin blood proteins thin films by matrix assisted pulsed laser evaporation,” Appl. Surf. Sci., 252 4652 –4655 (2006). 0169-4332 Google Scholar

23. 

T. M. Patz, A. Doraiswamy, R. Narayan, N. Menegazzo, C. Kranz, B. Mizaikoff, R. Modi, and D. B. Chrisey, “Matrix assisted pulsed laser evaporation of poly (D, L) lactic acid films,” Mater. Res. Soc. Symp. Proc., 845 AA5.8.1 –AA5.8.6 (2005). 0272-9172 Google Scholar

24. 

B. Toftmann, M. R. Papantonakis, R. C. J. Auyeung, W. Kim, S. M. O’Malley, D. M. Bubb, J. S. Horwitz, J. Schou, P. M. Johansen, and R. F. Haglund, “UV and RIR matrix assisted pulsed laser deposition of organic MEH-PPV films,” Thin Solid Films, 453-454 177 –181 (2004). 0040-6090 Google Scholar

25. 

P. R. Willmott and J. R. Huber, “Pulsed laser vaporization and deposition,” Rev. Mod. Phys., 72 315 –328 (2000). https://doi.org/10.1103/RevModPhys.72.315 0034-6861 Google Scholar

26. 

F. Bloisi, A. Cassinese, L. Vicari, and V. Califano, “MAPLE deposited polythiophene films,” Thin Solid Films, 0040-6090 Google Scholar

27. 

F. Bloisi, L. Vicari, R. Papa, V. Califano, R. Pedrazzani, E. Bontempi, and L. Depero, “Biomaterial thin film deposition and characterization by means of MAPLE technique,” Mater. Sci. Eng., 0025-5416 Google Scholar

28. 

C. Pasquini, “Near infrared spectroscopy: fundamentals, practical aspects and analytical applications,” J. Braz. Chem. Soc., 14 198 –219 (2003). 0103-5053 Google Scholar

29. 

G. Kister, G. Cassanas, and M. Vert, “Effects of morphology, conformation and configuration on the IR and Raman spectra of various poly(lactic acid)s,” Polymer, 39 276 –273 (1998). 0032-3861 Google Scholar

30. 

B. Toftmann, K. Rodrigo, J. Schou, and R. Pedrys, “High laser-fluence deposition of organic materials in water ice matrices by MAPLE,” Appl. Surf. Sci., 247 211 –216 (2005). https://doi.org/10.1016/j.apsusc.2005.01.175 0169-4332 Google Scholar

31. 

K. Rodrigo, P. Czuba, B. Toftmann, J. Schou, and R. Pedrys, “Surface morphology of polyethylene glycol films produced by matrix-assisted pulsed laser evaporation (MAPLE): Dependence on substrate temperature,” Appl. Surf. Sci., 252 4824 –4828 (2006). https://doi.org/10.1016/j.apsusc.2005.07.143 0169-4332 Google Scholar

32. 

S. Wang, W. Cui, and J. Bei, “Bulk and surface modifications of polylactide,” Anal. Bioanal. Chem., 381 547 –556 (2005). 1618-2642 Google Scholar
©(2008) Society of Photo-Optical Instrumentation Engineers (SPIE)
Valeria Califano, Francesco Bloisi, Luciano Rosario Maria Vicari, Oana Bretcanu, and Aldo R. Boccaccini "Matrix-assisted pulsed laser evaporation of poly(D,L-lactide) for biomedical applications: effect of near infrared radiation," Journal of Biomedical Optics 13(1), 014028 (1 January 2008). https://doi.org/10.1117/1.2830660
Published: 1 January 2008
Lens.org Logo
CITATIONS
Cited by 14 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Polymers

FT-IR spectroscopy

Pulsed laser operation

Molecules

Biomedical optics

Biopolymers

Ultraviolet radiation

Back to Top