1.IntroductionThe retina and optic nerve are complex neural tissues originating from the diencephalon and connected to the central nervous system (CNS), where visual processing takes place in the visual cortex. The retina shares many similarities with the cerebral cortex, such as ganglion cells with the typical morphology of CNS neurons. It has been shown that many CNS diseases, including multiple sclerosis, Alzheimer’s disease, and Parkinson’s disease, can also be detected on the retina level.1 Given that around 80% of external information is processed through visual perception2 and with retina-related blindness being a significant global health issue,3 understanding retinal structure and function, vascular hemodynamics, and neurovascular coupling is of paramount importance.4 For example, retinal ganglion cell axons are nonmyelinated within the retina. Thus, the retinal nerve fiber layer (NFL) is an optimal structure for visualizing the process of neurodegeneration, neuro-protection, and neuro-repair.5 Moreover, despite extensive studies of alterations to blood circulation in the CNS and optic nerve in neurological and neuro-ophthalmological diseases, it is still unclear whether the vascular alterations are secondary to neuronal loss from decreased metabolic demand and neurovascular coupling or a pathogenic step preceding neurodegeneration. Retinal vascular features, including vascular attenuation, tortuosity, and foveal avascular zone alterations, as well as structural changes in retinal and choroidal layer thickness, have received increasing attention in the setting of neurological and neuro-ophthalmological diseases.6 The retina is conveniently located at the imaging plane of the optical system of the eye, thus providing not only a “window” to a sensory peripheral of the brain but also the opportunity for non-invasive observation of alterations associated with neurodegenerative conditions and changes in neural tissue vasculature.7 Recent advancements in retinal imaging are enabling the exploitation of this potential.4 Scanning laser ophthalmoscopy (SLO)8 and optical coherence tomography (OCT)9 are two complementary in vivo retinal imaging modalities that have often been combined with adaptive optics (AO) to successfully image the photoreceptor mosaic, the retinal microvasculature,10–12 and the highly transparent ganglion cell somas in the human inner retina13,14 and its temporal dynamics.15 Retinal blood flow can be monitored quantitatively in vivo through laser speckle flowgraphy,16 a technique that produces angiographic contrast from speckle variance, allowing for full-field blood flow measurements (in arbitrary units) with a high temporal resolution. Alternatively, laser Doppler flowmetry17 can measure blood flow and mean velocity in relative units, and with its full-field extension, laser Doppler holography (LDH)18 can estimate retinal pulsatile flow over a lateral field of view (FOV) with a millisecond resolution. The aforementioned techniques lack depth sectioning ability, making the influence of choroidal flow unclear. However, it would be beneficial to analyze choroidal hemodynamics19,20 separately from that of the inner retina and at high temporal resolution. OCT angiography (OCT-A)21,22 and Doppler OCT23 provide depth-sectioned hemodynamic information; however, these approaches have been most commonly implemented with flying-spot OCT systems, where the limited volumetric imaging rates restrict the temporal resolution needed to monitor the blood flow during a cardiac cycle within the vascular network in 3D. Fourier-domain full-field optical coherence tomography (FD-FF-OCT) overcomes the acquisition speed issue, and it has been employed for functional neuronal analysis24,25 and hemodynamic analysis, including pulse wave propagation in human retinal vessels26 and in combination with LDH.27 Choroidal vessel visibility, though, remains limited in structural FD-FF-OCT images due to coherent crosstalk noise that limits imaging of deeper layers located in scattering media. Spatio-temporal optical coherence tomography (STOC-T), a variant of FD-FF-OCT28,29 suppressing crosstalk via spatio-temporal optical phase manipulation,30 has demonstrated an enhanced ability to image the full thickness of the chorio-retinal complex,31 and thanks to its high phase stability and ultrafast volumetric imaging rate, it has been successfully employed in functional imaging of photoreceptor response in humans.32,33 The application of the aforementioned optical retinal imaging techniques in mice34 is particularly important as rodents serve as a primary animal model for exploring not only fundamental aspects of vision science and ophthalmic research,35–37 including investigations into phototransduction mechanisms,38,39 but also broader applications in the field of general neuroscience.7 Various groups studied neurovascular coupling in rodents subject to flicker stimulation.40,41 Inner retinal blood flow has been monitored with LDH in rodents at a temporal resolution of .42 Ultrahigh-resolution images of the mouse retina have been acquired with visible light OCT43 and AO-SLO.44 Zhang et al.45,46 demonstrated in vivo cellular resolution neuronal and vascular retinal imaging in mice without AO and, more recently, with AO.47 A sensorless AO approach has also provided volumetric cellular imaging of microglia throughout the inner retina.48 Although these advances show tremendous progress toward elucidating the relationship between the neuronal and vascular retinal tissues in health and disease models, the use of STOC-T in mouse retinal imaging would hold promise to complement the aforementioned techniques by providing high-resolution imaging down to the choriocapillaris,31 several hemodynamic signals at millisecond temporal resolution for angiography and neurovascular coupling, and functional information within the same system. In fact, owing to its high phase stability within a single volume, digital aberration correction (DAC) can be applied49,50 to approach the resolution obtained with AO, whereas phase stability over consecutive volumes would allow retinal functional and hemodynamic signal measurements, including quantitative information about the retinal tissue expansion from blood vessel pulsation, useful in the study of neuro-vascular coupling and vascular and optic nerve head biomechanics.51,52 Meanwhile, STOC-T structural 3D images of the retina would allow the monitoring of dynamic changes at a temporal resolution of a few milliseconds. This work describes a STOC-T system designed for ultrafast volumetric mouse retinal imaging that can be controlled to focus on a specific retinal or choroidal vascular bed in the mouse eye, using a calibrated fundus imaging system. The STOC-T image processing with numerical dispersion compensation, DAC, and volume co-registration with sub-pixel precision attains high-spatial and temporal resolution retinal and choroidal images. A simple STOC-T amplitude-only processing allows the extraction of pulse traces from different retinal and choroidal vessels, the estimate of pulse wave velocities in capillaries, and the evaluation of arterial and venous pulse delay. On the other hand, phase-sensitive processing enables retrieval of other hemodynamic signals, including tissue displacement caused by blood vessel pulsation. 2.MethodologyThe proposed high-speed volumetric mouse retinal imaging system and its application to vascular hemodynamics involve the development of a custom optical setup and several data processing steps described in the Secs. 2.1–2.7. The optical setup, presented in Fig. 1, is based on the following features: a STOC-T imaging system comprising a Michelson interferometer with a sample interface that can compensate for the mouse eye refractive error53 and a white-light fundus imaging system54 for aiding the mouse’s eye alignment. 2.1.Mouse Retinal STOC-T Imaging SystemThe STOC-T imaging technique combines FD-FF-OCT with control over the spatial coherence characteristics of the employed near-infrared (NIR) light, with the added benefit of reducing the influence of coherent crosstalk noise, and therefore accessing deeper layers in the eye.31 Spatial coherence reduction is achieved by delivering NIR light from a swept-source laser to the optical interferometer via a long multimode (MM) fiber, creating many temporally incoherent spatial modes (TEMs). At the detector, the TEMs cause an incoherent summation of interference signals adding constructively when the angular spectrum of the TEM scattered by the sample matches that of the corresponding TEM reflected from the reference mirror. Thus, the interference of TEMs that are strongly distorted by scattering has a very low contrast, reducing the contribution of the crosstalk noise to the interferometric signal.55 More specifically, NIR light from the swept-source laser (BS-840-2-HP, Superlum, Co. Cork, Ireland) is delivered to the system via 300 m of an MM fiber with a core diameter (FG050LGA, Thorlabs, Newton, New Jersey, United States).55,56 Light is then collimated by an aspheric lens collimator (APC22-780, Thorlabs), expanded by a telescope comprising two achromatic doublet lenses () and (), and split into the reference arm and the sample arm by a beam splitter. The optical components in the sample arm comprise an achromatic doublet lens () and a zero-diopter (0 D) meniscus lens (Cantor & Nissel, Brackley, United Kingdom) with lubricant gel (Vidisic, Bausch & Lomb, Rochester, New York, United States) as the sample interface. The mouse eye is brought in contact with the gel, and the gel thickness is adjusted by manipulating the mouse position with respect to the meniscus lens. Lens focuses the image of the MM fiber tip near the front focal plane of the mouse eye. Therefore, the mouse retina is illuminated by a low-divergence beam creating an illumination area on the retina with a diameter of . NIR light backscattered by the retina propagates back through the eye, , and the beam splitter to form an image of the retina in an intermediate conjugate plane relayed to the sensor of a high-speed camera (Nova S16, Photron, Tokyo, Japan) by a 1:1 telescope comprising two 2” achromatic doublet lenses and () in the detection path. An iris is introduced in a conjugate plane of the mouse pupil behind to control the aperture of the system and, therefore, the lateral resolution and depth of field (DOF). Light in the reference arm gets reflected by a silver mirror after propagating through an achromatic doublet () and a small plano-convex lens (, 2.5 mm aperture) that mimics the focal length of the mouse eye to provide a similar field curvature at the STOC-T camera as the one from the sample arm. A neutral density filter is used to optimize the reference arm power within the STOC-T camera dynamic range to maximize the sensitivity. The STOC-T system performs a sweep of the laser from 803 to 878 nm linearly in wavenumber units, whereas the ultrafast camera records 512 images with a resolution of 512 by 448 pixels at a frame rate of 60,000 fps. This results in a volumetric scan rate of , meaning that hemodynamic signals within the captured volume can be analyzed every 8.9 ms. Additional specifications of the mouse retinal STOC-T system are reported in Table 1. Table 1Mouse retinal volumetric imaging system specifications
2.2.Mouse Eye Fundus Imaging SystemThe mouse retinal volumetric imaging system includes a mouse eye fundus imaging system. This consists of a white light LED source (MWWHL4, Thorlabs) followed by a telescope, comprising two achromatic doublet lenses () and (), forming a conjugate image at a position where we introduced an amplitude mask, shaping the source as an annulus. The annulus image is relayed by the achromatic doublet lens (), via a dichroic mirror (DMLP650, Thorlabs), and lens onto the meniscus lens front surface. This produces two effects: it avoids specular reflection from the meniscus lens apex, which would severely degrade the contrast of the fundus image, and it goes on to illuminate the mouse retina in a Kohler illumination scheme. White light backscattered from the mouse eye fundus propagates through the mouse eye, gel and meniscus lens, lens , the beam splitter, lens , the dichroic mirror (#69-207, Edmund Optics, Barrington, New Jersey, United States), and the achromatic doublet lens () in the detection path to focus on the fundus camera (ac1300-200um, Basler, Highland, Illinois, United States). The fundus imaging system specifications are reported in Table 1. Fundus image processing involves background subtraction from the raw fundus images to further reduce stray reflections that reduce the image contrast. The background image was acquired with the mouse eye separated from the meniscus lens by a substantial amount of gel, before bringing the fundus into focus by moving the mouse closer to the meniscus lens. 2.3.Imaging Mouse Eyes In VivoThe study described in the paper was approved by the First Local Ethics Committee for Animal Experiments in Warsaw regarding all protocols for mouse rearing and handling (resolution no 1401P3/2022). Albino (balb/c) and wild-type (C57/BL6) mice were obtained from the Nencki Institute of the Polish Academy of Sciences, in Warsaw, Poland. Transparent lubricant gel (Vidisic, Bausch & Lomb) was applied to the mouse eye to prevent cold cataracts and to maintain the hydration and transparency of the eye anterior segment. During the experimental procedure, mice were anesthetized with 1.5% isoflurane (Vetflurane 100 mg/g, Virbanc, Carros, France), delivered in , and maintained on an adjustable platform equipped with a heating blanket (additional details in the Appendix C). Mouse pupils were dilated with medical-grade tropicamide (Tropicamidum WZF 1%, Polfa Warszawa, Warsaw, Poland) and phenylephrine (Neosynephrin-POS 10%, Ursapharm, Saarbrucken, Germany). In terms of mouse eye safety from photothermal damage, there are no standards for maximum permissible exposure (MPE), and studies on rat retinas57 have shown that it is not easy to translate the human retina MPE to rodents by simply scaling based on numerical aperture. However, we carefully evaluated that no damage was visible in the mouse retina after our measurements and confirmed its retained functionality with electrophysiology tests. 2.4.Mouse Refractive Error CompensationMouse eyes can present refractive errors, and it is reported that mouse eyes are generally hyperopic;58 therefore, a method to compensate for their refractive error and, at the same time, ensure proper focus control of the STOC-T retinal image on a specific retinal layer or vascular bed of interest is very important. In our system, we implemented a sample interface that can compensate for the mouse eye refractive error by adjusting the distance of the mouse eye to a stationary 0 D meniscus lens in lubricant eye gel, as in the work of Zhang et al.53 As soon as the meniscus lens is no longer preceded and followed by the same medium, i.e., as soon as it is in contact with the gel on the mouse side, it becomes a positive lens. Therefore, changing the axial position of the mouse’s eye makes it possible to change the thickness of the gel and bring the retinal layer of interest into focus on the STOC-T camera. The appropriate gel thickness depends on the meniscus lens curvature, with smaller radii of curvature (i.e., more curved meniscus lenses) requiring less gel. Similarly, for a given meniscus lens curvature, myopic eyes (i.e., eyes with a longer axial length than normal) require less gel than emmetropic eyes (i.e., eyes with no refractive error), and hyperopic eyes (i.e., eyes with shorter axial length than normal) require more gel than emmetropic eyes. Figure 2 graphically shows the appropriate gel thickness to have a focused image of the photoreceptor layer in ray tracing optical models of our system and of a mouse eye59 [Fig. 2(a)] and the mouse eye phantom, described in detail in Appendix A [Fig. 2(b)], as a function of meniscus lens curvature [Fig. 2(c)], and as a function of the mouse refractive error [Fig. 2(d)]. For reference, the emmetropic eye axial length was 3.4 and 2.31 mm in the mouse eye and the mouse eye phantom ray tracing models, respectively. 2.5.STOC-T Image Processing and Digital Aberration CorrectionSTOC-T image reconstruction and processing followed the pipeline described in detail in our previous work.31–33 However, the STOC-T processing pipeline differed slightly depending on whether or not DAC was incorporated.50 In summary, STOC-T volumes were reconstructed by applying the following algorithmic sequence: MM speckle noise reduction by en face spatial frequency filtering, selection of the region of interest in depth (Z), numerical dispersion compensation, fast Fourier transformation along the wavenumber axis (i.e., the time axis), and normalization by the noise floor. If no DAC was required, the next step was volume flattening within each volume in the dataset, applied by detecting Bruch’s Membrane (BrM) depth and by co-registering all A-scans to it. Volume co-registration was the following step, whereby all volumes in the dataset were co-registered to the first volume, initially in Z to BrM depth and then in the X and Y planes. If DAC was required, the processing applied to the reconstructed volumes was as follows. The complex data of each reconstructed volume were 2D-Fourier transformed at each depth Z, to obtain the spatial spectrum. This was multiplied by a complex exponential function of an adjustable parameter and a Zernike polynomial . The resulting product was then 2D-inverse-Fourier transformed to obtain a phase-corrected reconstructed en face image. Several values of the parameter are tried until the kurtosis , an image sharpness metric, of the en face image intensity is maximized. In the simplest form, only the defocus Zernike polynomial is considered (with indices and ). Alternatively, at the expense of a higher computational demand, up to 22 Zernike polynomials for each en face image have been considered. Once each volume in the dataset underwent DAC, a 3D (, and ) co-registration procedure was applied so that all volumes in the dataset were co-registered to the first one. This was followed by volume flattening. 2.6.Phase Stability of the SystemThe mouse eye phantom was also used to determine the phase stability of the STOC-T system by evaluating the best inter-layer displacement sensitivity, i.e., the sensitivity to displacement over time between two depth layers in the same volume, for phantom layers presenting a similar signal-to-noise ratio (SNR) to, for example, the mouse NFL layer and the BrM. To do so, two layers of adhesive tape were laid on top of the USAF test target, to create closely spaced layers of realistic SNR. Equation (1) computes the STOC-T theoretical inter-layer displacement sensitivity from the theoretical inter-layer phase difference sensitivity , where the symbol indicates a double phase difference operation, i.e., between layers and over time, as The theoretical inter-layer phase difference sensitivity 60 is inversely related to half the composite SNR, , arising from the different SNRs of the two retinal layers of interest, and , where . It follows from Eq. (2) that The SNR of the top of the air-tape interface of the top layer was , whereas the SNR of the interface between the two tape layers was . Therefore, the composite STOC-T SNR from the two layers is 21.4 dB for the central () position in the FOV. The theoretical inter-layer displacement sensitivity is 27.6 nm. The corresponding experimental inter-layer displacement sensitivity was 26.2 nm, where reduced adhesiveness between tape layers over time, , might have contributed to an increase in , leading to a result slightly better than expected. Moreover, at the cost of reducing the lateral resolution, magnitude averaging among areas of (independent) pixels could improve the SNR by a factor of .61 For a local average in a central region of 15 by 15 lateral pixels and three depth pixels, the measured STOC-T inter-layer displacement sensitivity further improved to 1.2 nm. This size region, corresponding roughly to , is the one we chose for phase-sensitive hemodynamics measurements. We also evaluated the displacement sensitivity of the system during an in vivo measurement of a mouse retina as this is a more relevant parameter. However, several factors render this measurement complicated. First, the mouse eye moves slightly during the acquisition, and therefore, it is important that the volume co-registration algorithm works well. Even in such a case, we can expect that the mouse motion might have introduced some additional noise to the phase-sensitive measurement. Second, in an in vivo measurement, the retinal layer (NFL–BrM) displacement induced by the blood pulse wave, i.e., one of the parameters we would like to quantify for hemodynamic analysis, is present on top of the noise floor we want to evaluate for a displacement sensitivity assessment. Therefore, to minimize the pulsation-induced retinal displacement influence, we subtracted the intra-layer displacement over time between neighboring regions and obtained an equivalent inter-layer displacement sensitivity of 5.8 nm. 2.7.Hemodynamics AnalysisWe performed two types of hemodynamics analysis. The first one derives from the computation of the spatially resolved STOC-T signal amplitude variation over time, which is useful for highlighting the position of blood vessels forming the retinal and choroidal vasculature. The comparative analysis of the temporal pulse traces from different vessels and from different locations along some vessels enables the characterization of phase differences (delays) between arterial and venous pulsation and pulse wave velocity (in plane), respectively. In addition, STOC-T axial sectioning enables this comparative analysis for different vascular beds in the chorioretinal complex. The second type of analysis derives from the computation of the spatially resolved STOC-T phase among different retinal layers (en face) over time. By choosing the NFL as the layer of interest and the BrM as the reference layer, one can measure the retinal tissue displacement in the order of tens to hundreds of nanometers over time due to pulse wave propagation. More specifically, we calculate the phase differences over time to the first time point for the NFL and BrM for a range of 3-depth pixels. Then, we calculate, pairwise, the phase difference between NFL and BrM and average it over the depth dimension. Then, we apply Gaussian filtering with a kernel parameter equal to 5 pixels. We mask out regions of low STOC-T amplitude. Then, we first perform lateral phase unwrapping,62,63 followed by phase unwrapping in time. We cut out phase difference values exceeding , corresponding to wrapping artifacts around and above vessels. We then translate phase differences to tissue displacement, using Eq. (1).60 3.ResultsFigure 3 shows examples of the type of volumetric structural images of the mouse retina and choroid that can be obtained with our high-speed STOC-T system. Figures 3(a)–3(e) are images from a wild-type mouse retina, whereas Figs. 3(f)–3(k) are images from an albino mouse retina. All images are the results of magnitude averaging from 60 co-registered DAC-processed volumes acquired in 0.532 s. DAC took place by correcting the first 22 Zernike terms. Figures 3(a) and 3(f) present an average of 10 central B-scans, highlighting the layered structure of the mouse retina. In both, dashed color lines at increasing depth in the retina indicate, in order, the location of the NFL, the inner plexiform layer (IPL), and the photoreceptor inner and outer segment (IS/OS) junction and the choroid, which are shown in en face images boxed with the corresponding color in Figs. 3(a) and 3(f). The NFL images [Figs. 3(b) and 3(g)] and the IPL images [Figs. 3(c) and 3(h)] are the result of a 10-depth pixel average; the IS/OS images [Figs. 3(d) and 3(j)] are the result of a 20-depth pixel average; and the choroidal images [Figs. 3(e) and 3(k)] are the result of a 65-depth pixel average. Importantly, larger blood vessels are visible in both the superficial layers, e.g., the NFL, and in the choroid, whereas a more intricate network of smaller vessels and capillaries is visible in the IPL. The IS/OS junction image reveals a speckle pattern reminiscent of the underlying photoreceptor mosaic, although not fully resolved, as resolving individual rods in mice proved to be complicated if not elusive to AO techniques too.46,47,64 In the following steps, we extracted hemodynamics information, captured by the high-volume rate of the system, by visualizing how the amplitude of STOC-T changes at different depths over time. The results are depicted in Fig. 4. In this hemodynamics study, we specifically focused on a single mouse model to maintain consistency and provide a clear demonstration of retinal hemodynamics using the STOC-T system. Investigating subtle differences between mouse types requires detailed quantitative analysis within one model to establish a baseline, which can then serve as a reference for future comparative research. Figures 4(a)–4(c) show STOC-T en face images of an albino mouse retinal layer just below the NFL, a layer in the choroid, and the outer plexiform layer (OPL), respectively, generated by magnitude averaging in the depth-ranges indicated in Fig. 4(d) and then also averaging in time (340 volumes, 3.0147 s). Figure 4(e) presents the deviation from the mean pixel amplitude in time, averaged in small regions of blood vessels, just below the NFL and in the choroid, in cyan and orange color, respectively. These regions, including blood vessels branching, are highlighted by the shaded areas in the zoomed-up regions of interest (ROIs) in Figs. 4(a) and 4(b), respectively. A moving average filter with a five-sample window (44.3 ms) has been applied to smooth the curves. An interesting observation is that the mouse retinal superficial vessel and choroidal vessel pulsate both with a frequency of roughly 6 Hz but are nearly in phase opposition, corresponding to a delay of . Figure 4(f)—top—presents the ROI in the OPL with a green gradient arrow overlaid on a capillary, indicating the direction of blood flow. The flow could be observed with the time resolution of our system, and the group velocity of the pulse wave could be assessed. Figure 4(f)—bottom—presents a graph of the STOC-T signal amplitude variation over time for four different locations along the highlighted vessel (as indicated by the color gradient), with each curve first low-pass-filtered with a cut-off frequency of 6.25 Hz, averaged in a small region of the vessel, smoothed by the same moving average filter as in Fig. 4(e), and then normalized by each maximum to emphasize the wave propagation characteristics. It is evident that the pulse signal in such a small vessel is not as regular and it presents a broader bandwidth than the signal for the larger superficial and choroidal vessels. However, it can be noted that the peaks and throughs of the pulse temporal waveform move along the capillary at a quantifiable speed. This is even clearer from Fig. 4(g)—top—showing STOC-T signal amplitude variations averaged across the vessel thickness and shown as a map plotting time versus distance along the vessel direction. A slanted pattern is noticeable in this map, confirming a repeated observation of capillary blood flow. Figure 4(g)—bottom—allows us to estimate the group velocity of this pulse wave. In fact, it shows the corresponding 2D Fourier transform amplitude, presenting different frequency components grouped along a constant spatial frequency—temporal frequency ratio, corresponding to a specific propagation velocity, which can be estimated as . Video 1 shows a time sequence of STOC-T en face amplitude images, averaged through the depth-ranges indicated in the sliced volume cross-sections in Fig. 4(d). On the right, the same three layers are shown as a time sequence of the averaged en face images following Gaussian filtering, amplitude squaring, and temporal mean removal. These extra processing steps aid the visualization of blood vessel pulsation and pulse wave propagation as temporal black-to-white fluctuations over a rather constant gray background. Interestingly, we can observe how the pulse wave group velocity in larger superficial and choroidal vessels is too high for the system to detect, and the whole vessel within the FOV pulsates almost at the same time. This is in contrast to the smaller vessels and capillaries of the OPL, where the pulse wave propagation can be sampled with the high volumetric temporal resolution of our system. Video 2 shows the time sequence of the same dataset as in Video 1, for the NFL and choroidal layers and also for a B-scan cutting through a superficial vessel just below the NFL. This is useful to highlight how blood flow affects signal in depth in STOC-T. In fact, we can observe that the signal fluctuates not only at the vessel location depth but also above and below the vessel. In the graph, we plot the STOC-T amplitude over time for the average amplitude within the cyan and brown regions, corresponding to the location of the branching of the superficial vessel itself, and the same lateral location deep in the choroid, where no major vessel is visible, respectively. The signals were additionally filtered using a moving average filter with a five-sample window length. It is evident how the cyan and brown curves are opposite in phase as they mirror each other, i.e., once the signal in the superficial vessel peaks, the signal from the vessel projection in the choroid is at its minimum, and vice versa. By observing the B-scan, we can see that the signal appears to periodically concentrate around the superficial vessel and then deplete from the vessel location while smearing to neighboring depths, both below and importantly above, i.e., at shorter optical pathlengths. In Sec. 4, we elaborate on the likely cause of this phenomenon. Nevertheless, Video 2 confirms that the choroidal vessel pulsation is delayed from the superficial vessel pulsation, even when the lateral positions of the two vessels do not match. This allows us to rule out any artifactual nature of this delay, despite the fact that the phase offset between the two is incidentally in opposition, as reported also in Fig. 4(e). Therefore, this hints at differences in arterial versus venous vessel types. We continued the analysis of mouse retinal hemodynamics by distinguishing between venous and arterial pulsation in the mouse retina through STOC-T amplitude analysis. Figure 5(a) shows an image of an albino mouse retina acquired with the fundus camera providing an overview of the retinal region studied with the STOC-T system (outlined by the red box). In this case, out of the 340 volumes, 221 happened between mouse breathing events, so we focused on this more stabilized subset of volumes. The processing included DAC for defocus correction. Figure 5(b) presents a maximum amplitude projection of a 20-layer averaged en face image of the NFL, through time (i.e., through 221 STOC-T volumes). The vessel visibility is hindered by the surrounding scattering regions as it is common also in flying spot OCT. However, the high temporal resolution allows us to sample the blood flow pulsation-induced STOC-T amplitude signal variation and localize it to the vasculature outline. Figure 5(c) shows the en face image of the superficial vasculature by plotting the band-pass (0.5 Hz bandwidth) filtered amplitude of the signal spectrum at the heartbeat rate of 6 Hz. Figure 5(d) presents the phase of the 6 Hz signal component, revealing temporal differences attributable to the delay between arterial and venous pulsation. All phases are shifted by constant component () to keep the distribution around 0 value for presentation purposes. Figure 5(e) shows the mean-subtracted time series of the STOC-T amplitude averaged within three specific 15 by 15-pixel regions marked in Fig. 5(c), filtered with a moving average of nine samples (79.8 ms window). The curves highlight the predominant contribution of blood vessels (cyan curve) to the observed STOC-T amplitude oscillations (compared with the green curves from just outside the vessel). We evaluated the delay between the pulse traces of two vessels in the areas marked by a dashed black line in Fig. 5(d). We reported the average peak delay to be 29 ms in Fig. 5(f), showing mean-subtracted time series of the STOC-T amplitude averaged inside the regions bounded by the two dashed black lines in Fig. 5(d), filtered with a moving average of five samples (44.3 ms window). Figure 5(g) presents a normalized histogram (pixel counts per radian) of the phase values of pixels within the regions bounded by the two dashed black lines in Fig. 5(d) (with bin width 0.1 radians, and the pixel counts smoothed with a moving average filter of a 5-bin window length). The temporal separation between these two distributions confirms the results shown in Fig. 5(f). The exquisite temporal resolution of our STOC-T system enabled the classification of arterial and venous pulsation, delayed by only 29 ms, with the arteries (in orange) pulsating before the veins (in light blue). Last, we extracted additional hemodynamics and biomechanics information, captured by the high-volume rate of the system, by visualizing how the phase difference among different layers (depths) in a STOC-T volume changes over time. The results are depicted in Fig. 6. Figures 6(a) and 6(b) present tissue displacement maps, at 44 and 124 ms from the start of the STOC-T recording, respectively, separated roughly by half heartbeat cycle (period), overlaid to the filtered amplitude of the STOC-T signal spectrum at 6 Hz, as in Fig. 4(c). We can observe that the tissue responds to a pulsating vessel by expanding and contracting in sync with the pulse wave and how this displacement is mostly, but not entirely, concentrated above and around the vessels. In Fig. 6(c), we show the time plots of tissue displacement at two chosen locations, near an artery (pink box) and a vein (light blue box). To generate those plots, first, we average the tissue displacement over the chosen square region of 15 by 15 pixels, and then, we filter out signal frequency components below 2.5 Hz and apply a moving average filter with a five-sample window length. The average displacement modulation amplitude is roughly 100 and 150 nm near the artery and the vein, respectively. Also, a characteristic delay is present, albeit smaller than in corresponding Fig. 4(f). We calculated the delay between the two plots as the mean difference between corresponding signal peaks, and it was 15 ms. Video 3 presents a time sequence of both STOC-T en face amplitude images of the NFL of the mouse retina presented in Figs. 5 and 6 and an overlay of the corresponding mean-subtracted time sequence with the tissue displacement map. This visualization compiles complementary information about the spatially resolved hemodynamics and biomechanics analysis we can perform on the mouse retina. 4.DiscussionThe origin of the STOC-T amplitude variation with blood pulsation can be explained by the Doppler broadening65,66 caused by turbulent erythrocyte flow within the vessel18 (especially in the STOC-T axial direction) during the comparatively slow wavelength sweep (8.5 ms). During systole (when the cardiac muscles contract and blood pressure is maximum), the speed of circulating red blood cells is higher, and the corresponding Doppler broadening is larger than during diastole (when the cardiac muscles relax and the blood pressure is the lowest). As a result, the STOC-T signal at the depth where the blood vessel is located is at a minimum during systole as the signal is artifactually spread across a wider depth range, whereas it is at a maximum during diastole as the Doppler spread is reduced. However, the opposite trend happens at large distances below (and above) the blood vessel. In fact, systole-induced stronger Doppler broadening leaks noise onto the underlying signal, effectively leading to a maximum of the local STOC-T amplitude, whereas the added noise recedes during diastole, as it can be seen in Video 2. So, despite being artifactual in nature, the Doppler signal broadening variation gives us a surrogate signal to track blood pulse traces and flow velocities in capillaries. In addition, it allowed us to distinguish the arteries from the veins and identify the arteries themselves as they give a stronger signal than the vein during systole because of the higher speed of circulating red blood cells, which is in agreement with the results reported in the literature.18 The pulse wave velocity (in an en face plane) was too high to be detected in the larger superficial and choroidal vessels, but we could still detect it and measure it in the capillaries of the OPL. We measured a mean blood pulse group velocity of 0.35 mm/s, which is consistent with the literature, reporting mean blood flow velocities in the capillaries of the human retina to be below 3 mm/s67,68 and around 0.5 mm/s in the capillaries of the mouse retina.69 In our system, the upper bound for measurable pulse wave velocities in a straight vessel is . At the detected mouse heartbeat frequency of 6 Hz, this velocity should come from a pulse wave with a wavelength of , which is much larger than our FOV. Ultimately, the pulse wavelength might be a stronger limitation to measuring velocities in larger vessels than the temporal resolution of our system. Even for velocities in the order of 23 mm/s, i.e., the highest mean velocity in mouse retinal vessels reported in Ref. 69, the wavelength would be roughly 10 times the STOC-T FOV, making it hard to identify a crest (of the Doppler artifact) within a vessel, and there would only be two time points before that crest would disappear from the FOV. Nonetheless, we believe that our system is a powerful tool for monitoring pulse wave velocities in arterial and venous microvasculature in the retina and deep in the choroid. Moreover, our system can leverage its phase-sensitive ability to detect nanometer-range tissue displacement due to the traveling pulse wave. We noticed how tissue displacement above and near major vessels had modulation amplitudes between 100 and 150 nm, potentially carrying information about the biomechanical properties of the retinal layers involved. We also identified a delay in tissue displacement above a vein from the displacement above a neighboring artery. However, this delay (15 ms) was smaller than the delay measured from the analysis of the Doppler-induced STOC-T amplitude modulation (29 ms). This discrepancy could be in part due to slightly different response times of the tissues involved and their viscoelastic properties, but, more likely, to a phase-sensitive STOC-T measurement integrating contributions from several possible sources of tissue displacement beyond that of just the vessels of interest themselves. In fact, by calculating the displacement between Bruch’s membrane and the NFL, pulsation-induced motion at any depth between these two could contribute an out-of-phase component to the overall phasor sum, reducing the apparent delay between the two superficial pulsation-induced displacements. Last, in future studies, it will be beneficial to exchange the visible light illumination for the fundus imaging system with an IR LED to avoid retinal stimulation with visible light for studies where visual stimulation needs to be included, including long periods of dark adaptation, compatible only with an IR fundus imaging system. 5.ConclusionsIn summary, we demonstrated an experimental setup for mice retinal imaging based on the STOC-T technique, with a fundus camera and white light illumination aiding the alignment of the mouse. We presented en face images of the retinal and choroidal microstructure from various layers. The described experimental design facilitates the high-speed acquisition of high-quality, in vivo volumetric mouse retina imaging at a rate of 113 Hz and provides insight into the hemodynamics of the mouse retina and choroid that could be beneficial in the study of neurovascular coupling and vasculature and flow speed anomalies in neurological and neuro-ophthalmological conditions. 6.Appendix A: Mouse Eye PhantomA mouse eye optical phantom has been developed to calibrate the mouse retinal volumetric imaging system, to test its performance, and to measure several system specifications. The mouse eye phantom consists of a visible-NIR antireflection-coated plano-convex lens (#65-300, Edmund Optics), with a diameter of 2.5 mm and an effective focal length of 2 mm, glued on a custom-made 3D printed mount [see Fig. 2(b)]. The lens clear aperture and effective focal length resemble those of a mouse eye.70 A 2" × 2" negative, USAF 1951 high-resolution target (#55-622, Edmund Optics) mounted on an , and tip-tilt stage served as a phantom imaging plane, which could be set at the focal distance from the mouse eye phantom lens, simulating an emmetropic mouse retinal photoreceptor layer, or at different axial distances, simulating ametropia. Due to the lack of layered structure of the mouse eye phantom “retina,” we were using the USAF test target at two given positions, representing the photoreceptor and fundus layers, respectively, for any given mouse eye refractive error simulation. Through the help of ray tracing software (Zemax OpticStudio, Ansys, Canonsburg, United States), we determined the forward shift of the USAF test target from the position of the simulated photoreceptor layer needed to simulate the corresponding mouse eye fundus position. The whole mouse eye phantom was placed on , and stages, allowing to solidly move the eye phantom toward or away from the meniscus lens, with the mouse eye phantom lens able to get almost in contact with the meniscus lens within the mildly viscous gel. The mouse eye phantom was used to determine the lateral resolution and FOV of the imaging systems. The measured lateral resolution was 1.74 and 1.23 (corresponding to the last resolvable element of the USAF test target being the second and fifth elements from the eighth group), for the STOC-T and fundus imaging systems, respectively. 7.Appendix B: Imaging Systems Focal Offset Calibration Procedure and STOC-T Focus Fine TuningProper gel thickness selection and mouse alignment are crucial for obtaining good-quality STOC-T images. The best way to ensure proper mouse eye alignment and focusing on the retinal layer of interest before starting an STOC-T volumetric sequence acquisition would be by using a live STOC-T image preview combined with a proper precision optomechanical apparatus to align the mouse during live preview. Using the selected high-speed camera (Nova S-16, Photron), we encountered difficulties in implementing live preview due to the extended duration () needed to switch the camera from the recording to the data transfer mode. This transition time resulted in a live preview refresh rate of , which motivated us to incorporate a mouse fundus imaging system to provide a real-time preview. Moreover, as the NIR illumination is roughly collimated and STOC-T lacks the confocal effect by design, the variation in STOC-T signal-to-noise ratio (SNR) due to proper focusing is more subtle than that in standard flying-spot OCT; therefore, a visual evaluation of the B-scan intensity is not sufficient to accurately determine where the focus lies. The mouse fundus imaging system facilitates live preview and fine-tuning of the mouse position to adjust the focal plane position in the corresponding STOC-T volume as the evaluation of proper focusing of superficial retinal vessels, the optic nerve head, and possibly nerve fibers is more immediate in the fundus image than in the small FOV, low refresh rate STOC-T B-scans. The system works as follows: by adjusting the mouse position and the corresponding gel thickness until the white-light image of the mouse eye fundus appears to be centered around the region of interest and in focus on the fundus camera, we consequently bring the corresponding NIR STOC-T image of the mouse eye photoreceptor layer also in focus on the STOC-T camera (or another layer of interest, as per the following calibration procedure). To ensure that this is the case, a focal offset calibration procedure using the mouse eye phantom is performed. The fundus imaging system is calibrated by adjusting the position of lens [Fig. 7(a)] so that when the white-light image of the mouse eye phantom “fundus” appears in focus, the corresponding NIR STOC-T image of the mouse eye phantom “photoreceptor layer” is also in focus. As the distance of these equivalent layers in the mouse eye phantom imposes, after the meniscus lens, the vergence difference expected between rays originating from the corresponding retinal layers of an emmetropic mouse eye,59 we consider the calibration to be valid also for a generic emmetropic mouse eye. However, if the mouse eye under inspection presents an (unknown) refractive error, there will be a small disparity between the gel thickness we set by bringing the mouse eye fundus into focus on the fundus camera, and the one that would be required by the STOC-T camera to have the photoreceptor layer in focus [see Fig. 2(d)]. Moreover, this disparity increases with refractive error. Therefore, with the gel thickness set using live feedback from the fundus camera, we might experience a focal shift from the intended layer of interest in the retina in the STOC-T image. Figure 7(a) shows this effect in a vertical split optical ray tracing schematic, where (on the left) the top part represents the case of a mouse emmetropic eye and the bottom part represents the case of a mouse hyperopic eye. For the emmetropic eye, the focal offset system calibration leads, by design, to imaging the intended retinal layer in focus on the STOC-T camera. For a hyperopic eye, in the STOC-T image, there is a focal shift toward a deeper layer than intended [see close-up in Fig. 7(b)]. To assess the severity of this problem, we need to consider both the mouse refractive error and the imaging DOF, and how the latter is affected by the imaging system aperture control from the iris placed after lens . Basically, we can expect that if the focal shift is within the DOF, the calibration still holds, and we can still reasonably assume we are imaging the photoreceptor layer (or any other calibrated layer of interest) in focus on the STOC-T camera. We present the results of this analysis in Fig. 7(c), where one can see that if we close the iris to an aperture equivalent to a diameter of 1.5 mm in the conjugate mouse pupil plane, the DOF will be . In this case, the focal shifts from the retinal layer of interest in the STOC-T image would be acceptable only for mouse eye axial length variations of from the emmetropic condition. For an equivalent mouse pupil of 0.9 mm, axial length variations up to nearly , i.e., for most mouse eyes (with refractive errors below ), would produce shifts still within the DOF (). Obviously, reducing the pupil size, while it limits the effect of aberrations in the mydriatic mouse eye, reduces the theoretical (diffraction-limited) lateral resolution. This also means that the resolution limit that can be achieved with DAC is reduced. In most of the images presented in this paper, we maintained an equivalent pupil size between 1.5 and 1.2 mm. As a matter of fact, after the initial position of the mouse was adjusted based on feedback from the fundus camera, we fine-tuned the position based on the presence of increased speckle contrast due to the pulsation of the layer of interest, in a STOC-T preview screen, showing the raw frame (X and Y) from the STOC-T camera at a given wavelength. Figure 8 shows an example of the combined use of the fundus imaging system with the STOC-T system for volumetric mouse retinal imaging. Figure 8(a) displays the fundus image around the optic nerve of a wild-type mouse eye. The fundus camera FOV is useful for identifying features to guide the smaller STOC-T image FOV to areas of interest. The green box highlights the FOV for the STOC-T and planes, and the purple line shows the location of the and planes. The corresponding STOC-T en face image of the optic near the head with superficial vessels and B-scan is shown in Fig. 8(b). Figure 8(c) presents two B-scans at the same location, with the focal plane set on two different layers. The first one, inside a blue box, shows the case where the focal plane is set on (or near) the photoreceptor layer, after following the focusing procedure driven by the calibrated fundus camera image. The second one, inside a yellow box, shows the case where the mouse position was shifted around 200 mm backward (away from the meniscus lens) compared with the previous one. Figure 8(d) shows the corresponding line graphs of the averaged central A-scans, normalized to the choroidal signal peak of the image in the blue box. As noticeable on a closer visual inspection of Fig. 8(c), and from Fig. 8(d), the SNR shift from the outer retina and choroid toward the inner retina and NFL is detectable although not as pronounced as it would be in flying-spot OCT images with the equivalent confocal gate imposed by a relatively large pupil. Although this more uniform SNR with depth complicates the real-time evaluation of whether the focal tuning procedure worked as intended, it gives a better chance for DAC to work at several depths, owing to a higher starting SNR away from the focus. 8.Appendix C: Custom Mouse Positioning SystemOne of the issues encountered during the course of the study was the proper alignment of the mouse eye with the optical axis of the STOC-T imaging system. To address this, a customized mouse positioning system was developed. The design of this system is illustrated in Fig. 9. The optomechanical stage we used could be translated along the , and axes with motorized stages and had a gimbal-like mount to house the mouse body, which placed the pivot for the rotational degrees of freedom on or near the mouse right eye when the mouse teeth were biting a bar incorporated in a custom-designed 3D-printed nozzle connected to the tube to the anesthesia apparatus. This system facilitated consistent and repeatable positioning of the mouse, significantly speeding up the setup process. 9.Appendix D: Supplementary VideosVideo 1. Time sequence of STOC-T en face amplitude images of an albino mouse chorio-retinal complex, averaged through the depth-ranges indicated in the sliced volume cross-sections in Fig. 4(d). On the right, the same three layers are shown as a time sequence of the averaged en face images following Gaussian filtering, amplitude squaring, and temporal mean removal (MP4; 43810.215 kb [URL: https://doi.org/10.1117/1.NPh.11.4.045003.s1]). Video 2. Effect of mouse retinal blood flow on STOC-T signal in depth. Time sequence of the same dataset as in Video 1, for the NFL and choroidal layers and also for a B-scan cutting through a superficial vessel just below the NFL (MP4; 26689.648 kb [URL: https://doi.org/10.1117/1.NPh.11.4.045003.s2]). Video 3. Spatially-resolved hemodynamics and biomechanics analysis performed with STOC-T on an albino mouse retina. Time sequence of both STOC-T en face amplitude images of the NFL of the mouse retina presented in Figs. 5 and 6 and an overlay of the corresponding mean-subtracted time sequence with the tissue displacement map (MP4; 16449.633 kb [URL: https://doi.org/10.1117/1.NPh.11.4.045003.s3]). DisclosuresM.W. and D.B. are founders and shareholders of the InCellVu start-up company. Other authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. Code and Data AvailabilityData underlying the results presented in this paper are not publicly available at this time but may be obtained from the corresponding author upon reasonable request. AcknowledgmentsWe would like to acknowledge Dr. Egidijus Auksorius at the Center for Physical Sciences and Technology (FTMC) in Vilnius, Lithuania, for useful discussions about the STOC-T system design. We also acknowledge funding from the Polish National Science Center (Grant Nos. 2020/38/L/ST2/00556, 2019/34/E/NZ5/00434, 2020/39/D/NZ4/01881, and 2022/47/B/NZ5/03023) and the Foundation for Polish Science (Grant Nos. MAB/2019/12 and FENG.02.01-IP.05-T005/23). The International Centre for Translational Eye Research (MAB/2019/12, FENG.02.01-IP.05-T005/23) project is carried out within the International Research Agendas Programme of the Foundation for Polish Science, co-financed by the European Union under the European Regional Development Fund. Robert J. Zawadzki acknowledges the support of the National Institutes of Health (Grant No. R01-EY031098). ReferencesA. London, I. Benhar and M. Schwartz,
“The retina as a window to the brain-from eye research to CNS disorders,”
Nat. Rev. Neurol., 9
(1), 44
–53 https://doi.org/10.1038/nrneurol.2012.227
(2013).
Google Scholar
C. Haupt and A. B. Huber,
“How axons see their way-axonal guidance in the visual system,”
Front. Biosci., 13 3136
–3149 https://doi.org/10.2741/2915
(2008).
Google Scholar
W. H. Organization,
“Blindness and vision impairment,”
https://www.who.int/news-room/fact-sheets/detail/blindness-and-visual-impairment
(.).
Google Scholar
J. Yi, A. Dubra and S. Farsiu,
“Special section guest editorial: advances in retinal imaging,”
Neurophotonics, 6
(4), 041101 https://doi.org/10.1117/1.NPh.6.4.041101
(2019).
Google Scholar
K. M. Galetta et al.,
“Optical coherence tomography (OCT): imaging the visual pathway as a model for neurodegeneration,”
Neurotherapeutics, 8
(1), 117
–132 https://doi.org/10.1007/s13311-010-0005-1
(2011).
Google Scholar
A. Pinhas et al.,
“Optical coherence tomography angiography in neurology and neuro-ophthalmology,”
OCT and Imaging in Central Nervous System Diseases: The Eye as a Window to the Brain, 523
–544 Springer International Publishing, Cham
(2020). Google Scholar
E. M. Normando, M. F. Cordeiro,
“Animal models in neuro ophthalmology,”
OCT and Imaging in Central Nervous System Diseases: the Eye as a Window to the Brain, 401
–426 Springer International Publishing, Cham
(2020). Google Scholar
R. H. Webb and G. W. Hughes,
“Scanning laser ophthalmoscope,”
IEEE Trans. Biomed. Eng., BME-28
(7), 488
–492 https://doi.org/10.1109/TBME.1981.324734 IEBEAX 0018-9294
(1981).
Google Scholar
D. Huang et al.,
“Optical coherence tomography,”
Science, 254
(5035), 1178
–1181 https://doi.org/10.1126/science.1957169 SCIEAS 0036-8075
(1991).
Google Scholar
R. J. Zawadzki et al.,
“Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging,”
Opt. Express, 13
(21), 8532
–8546 https://doi.org/10.1364/OPEX.13.008532 OPEXFF 1094-4087
(2005).
Google Scholar
Z. Liu et al.,
“Trans-retinal cellular imaging with multimodal adaptive optics,”
Biomed. Opt. Express, 9
(9), 4246
–4262 https://doi.org/10.1364/BOE.9.004246 BOEICL 2156-7085
(2018).
Google Scholar
Z. Liu et al.,
“Ultrahigh-speed multimodal adaptive optics system for microscopic structural and functional imaging of the human retina,”
Biomed. Opt. Express, 13
(11), 5860
–5878 https://doi.org/10.1364/BOE.462594 BOEICL 2156-7085
(2022).
Google Scholar
E. A. Rossi et al.,
“Imaging individual neurons in the retinal ganglion cell layer of the living eye,”
Proc. Natl. Acad. Sci. U. S. A., 114
(3), 586
–591 https://doi.org/10.1073/pnas.1613445114
(2017).
Google Scholar
Z. Liu et al.,
“Imaging and quantifying ganglion cells and other transparent neurons in the living human retina,”
Proc. Natl. Acad. Sci. U. S. A., 114
(48), 12803
–12808 https://doi.org/10.1073/pnas.1711734114
(2017).
Google Scholar
K. Kurokawa et al.,
“Suite of methods for assessing inner retinal temporal dynamics across spatial and temporal scales in the living human eye,”
Neurophotonics, 7
(1), 015013 https://doi.org/10.1117/1.NPh.7.1.015013
(2020).
Google Scholar
T. Sugiyama et al.,
“Use of laser speckle flowgraphy in ocular blood flow research,”
Acta Ophthalmol., 88
(7), 723
–729 https://doi.org/10.1111/j.1755-3768.2009.01586.x
(2010).
Google Scholar
C. E. Riva et al.,
“Laser Doppler flowmetry in the optic nerve,”
Exp. Eye Res., 55
(3), 499
–506 https://doi.org/10.1016/0014-4835(92)90123-A EXERA6 0014-4835
(1992).
Google Scholar
L. Puyo et al.,
“In vivo laser Doppler holography of the human retina,”
Biomed. Opt. Express, 9
(9), 4113
–4129 https://doi.org/10.1364/BOE.9.004113 BOEICL 2156-7085
(2018).
Google Scholar
A. Reiner et al.,
“Neural control of choroidal blood flow,”
Prog. Retin. Eye Res., 64 96
–130 https://doi.org/10.1016/j.preteyeres.2017.12.001 PRTRES 1350-9462
(2018).
Google Scholar
C. F. Geerling et al.,
“Changes of the retinal and choroidal vasculature in cerebral small vessel disease,”
Sci. Rep., 12
(1), 3660 https://doi.org/10.1038/s41598-022-07638-x SRCEC3 2045-2322
(2022).
Google Scholar
A. H. Kashani et al.,
“Optical coherence tomography angiography: a comprehensive review of current methods and clinical applications,”
Prog. Retin. Eye Res., 60 66
–100 https://doi.org/10.1016/j.preteyeres.2017.07.002 PRTRES 1350-9462
(2017).
Google Scholar
Y. Li and J. Tang,
“Blood vessel tail artifacts suppression in optical coherence tomography angiography,”
Neurophotonics, 9
(2), 021906 https://doi.org/10.1117/1.NPh.9.2.021906
(2022).
Google Scholar
R. A. Leitgeb et al.,
“Doppler optical coherence tomography,”
Prog. Retin. Eye Res., 41
(100), 26
–43 https://doi.org/10.1016/j.preteyeres.2014.03.004 PRTRES 1350-9462
(2014).
Google Scholar
C. Pfäffle et al.,
“Simultaneous functional imaging of neuronal and photoreceptor layers in living human retina,”
Opt. Lett., 44
(23), 5671
–5674 https://doi.org/10.1364/OL.44.005671 OPLEDP 0146-9592
(2019).
Google Scholar
C. Pfäffle et al.,
“Phase-sensitive measurements of depth dependent signal transduction in the inner plexiform layer,”
Front. Med., 9 885187 https://doi.org/10.3389/fmed.2022.885187
(2021).
Google Scholar
H. Spahr et al.,
“Imaging pulse wave propagation in human retinal vessels using full-field swept-source optical coherence tomography,”
Opt. Lett., 40
(20), 4771
–4774 https://doi.org/10.1364/OL.40.004771 OPLEDP 0146-9592
(2015).
Google Scholar
L. Puyo et al.,
“Retinal blood flow imaging with combined full-field swept-source optical coherence tomography and laser Doppler holography,”
Opt. Lett., 47
(5), 1198
–1201 https://doi.org/10.1364/OL.449739 OPLEDP 0146-9592
(2022).
Google Scholar
E. Auksorius, D. Borycki and M. Wojtkowski,
“Crosstalk-free volumetric in vivo imaging of a human retina with Fourier-domain full-field optical coherence tomography,”
Biomed. Opt. Express, 10
(12), 6390
–6407 https://doi.org/10.1364/BOE.10.006390 BOEICL 2156-7085
(2019).
Google Scholar
P. Stremplewski et al.,
“In vivo volumetric imaging by crosstalk-free full-field OCT,”
Optica, 6
(5), 608
–617 https://doi.org/10.1364/OPTICA.6.000608
(2019).
Google Scholar
D. Borycki et al.,
“Spatiotemporal optical coherence (STOC) manipulation suppresses coherent cross-talk in full-field swept-source optical coherence tomography,”
Biomed. Opt. Express, 10
(4), 2032
–2054 https://doi.org/10.1364/BOE.10.002032 BOEICL 2156-7085
(2019).
Google Scholar
E. Auksorius et al.,
“Spatio-temporal optical coherence tomography provides full thickness imaging of the chorioretinal complex,”
iScience, 25
(12), 105513 https://doi.org/10.1016/j.isci.2022.105513
(2022).
Google Scholar
S. Tomczewski et al.,
“Light-adapted flicker optoretinograms captured with a spatio-temporal optical coherence-tomography (STOC-T) system,”
Biomed. Opt. Express, 13
(4), 2186
–2201 https://doi.org/10.1364/BOE.444567 BOEICL 2156-7085
(2022).
Google Scholar
S. Tomczewski et al.,
“Chirped flicker optoretinography for in vivo characterization of human photoreceptors’ frequency response to light,”
Opt. Lett., 49
(9), 2461
–2464 https://doi.org/10.1364/OL.514637 OPLEDP 0146-9592
(2024).
Google Scholar
R. K. Meleppat et al.,
“On-axis full-field swept-source optical coherence tomography for murine retinal imaging,”
Opt. Lett., 49
(16), 4630
–4633 https://doi.org/10.1364/OL.531116 OPLEDP 0146-9592
(2024).
Google Scholar
B. Chang et al.,
“Retinal degeneration mutants in the mouse,”
Vision Res., 42
(4), 517
–525 https://doi.org/10.1016/S0042-6989(01)00146-8
(2002).
Google Scholar
B. Chang et al.,
“Mouse models of ocular diseases,”
Vis. Neurosci., 22
(5), 587
–593 https://doi.org/10.1017/S0952523805225075 VNEUEY
(2005).
Google Scholar
M. D. Fischer et al.,
“Noninvasive, in vivo assessment of mouse retinal structure using optical coherence tomography,”
PLoS One, 4
(10), e7507 https://doi.org/10.1371/journal.pone.0007507 POLNCL 1932-6203
(2009).
Google Scholar
G. J. Chader,
“Animal models in research on retinal degenerations: past progress and future hope,”
Vision Res., 42
(4), 393
–399 https://doi.org/10.1016/S0042-6989(01)00212-7
(2002).
Google Scholar
P. Zhang et al.,
“In vivo optophysiology reveals that G-protein activation triggers osmotic swelling and increased light scattering of rod photoreceptors,”
Proc. Natl. Acad. Sci. U. S. A., 114
(14), E2937
–E2946 https://doi.org/10.1073/pnas.1620572114
(2017).
Google Scholar
T. Son et al.,
“Optical coherence tomography angiography of stimulus evoked hemodynamic responses in individual retinal layers,”
Biomed. Opt. Express, 7
(8), 3151
–3162 https://doi.org/10.1364/BOE.7.003151 BOEICL 2156-7085
(2016).
Google Scholar
B. Tan et al.,
“The effect of acutely elevated intraocular pressure on the functional and blood flow responses of the rat retina to flicker stimulation,”
Investig. Ophthalmol. Vis. Sci., 58
(12), 5532
–5540 https://doi.org/10.1167/iovs.17-22412 IOVSDA 0146-0404
(2017).
Google Scholar
M. Pellizzari et al.,
“High speed optical holography of retinal blood flow,”
Opt. Lett., 41
(15), 3503
–3506 https://doi.org/10.1364/OL.41.003503 OPLEDP 0146-9592
(2016).
Google Scholar
I. Rubinoff et al.,
“Speckle reduction in visible-light optical coherence tomography using scan modulation,”
Neurophotonics, 6
(4), 041107 https://doi.org/10.1117/1.NPh.6.4.041107
(2019).
Google Scholar
Y. Geng et al.,
“Adaptive optics retinal imaging in the living mouse eye,”
Biomed. Opt. Express, 3
(4), 715
–734 https://doi.org/10.1364/BOE.3.000715 BOEICL 2156-7085
(2012).
Google Scholar
P. Zhang et al.,
“In vivo wide-field multispectral scanning laser ophthalmoscopy-optical coherence tomography mouse retinal imager: longitudinal imaging of ganglion cells, microglia, and Muller glia, and mapping of the mouse retinal and choroidal vasculature,”
J. Biomed. Opt., 20
(12), 126005 https://doi.org/10.1117/1.JBO.20.12.126005 JBOPFO 1083-3668
(2015).
Google Scholar
P. Zhang et al.,
“Temporal speckle-averaging of optical coherence tomography volumes for in-vivo cellular resolution neuronal and vascular retinal imaging,”
Neurophotonics, 6
(4), 041105 https://doi.org/10.1117/1.NPh.6.4.041105
(2019).
Google Scholar
P. Zhang et al.,
“Adaptive optics scanning laser ophthalmoscopy and optical coherence tomography (AO-SLO-OCT) system for in vivo mouse retina imaging,”
Biomed. Opt. Express, 14
(1), 299
–314 https://doi.org/10.1364/BOE.473447 BOEICL 2156-7085
(2023).
Google Scholar
D. J. Wahl et al.,
“Sensorless adaptive optics multimodal en-face small animal retinal imaging,”
Biomed. Opt. Express, 10
(1), 252
–267 https://doi.org/10.1364/BOE.10.000252 BOEICL 2156-7085
(2019).
Google Scholar
D. Hillmann et al.,
“Aberration-free volumetric high-speed imaging of in vivo retina,”
Sci. Rep., 6 35209 https://doi.org/10.1038/srep35209 SRCEC3 2045-2322
(2016).
Google Scholar
D. Borycki et al.,
“Computational aberration correction in spatiotemporal optical coherence (STOC) imaging,”
Opt. Lett., 45
(6), 1293
–1296 https://doi.org/10.1364/OL.384796 OPLEDP 0146-9592
(2020).
Google Scholar
G. Garhofer et al.,
“Retinal neurovascular coupling in diabetes,”
J. Clin. Med., 9
(9), 2829 https://doi.org/10.3390/jcm9092829
(2020).
Google Scholar
M. M. Solano et al.,
“Mapping pulsatile optic nerve head deformation using OCT,”
Ophthalmol. Sci., 2
(4), 100205 https://doi.org/10.1016/j.xops.2022.100205
(2022).
Google Scholar
P. Zhang et al.,
“Effect of a contact lens on mouse retinal in vivo imaging: effective focal length changes and monochromatic aberrations,”
Exp. Eye Res., 172 86
–93 https://doi.org/10.1016/j.exer.2018.03.027 EXERA6 0014-4835
(2018).
Google Scholar
O. P. Kocaoglu et al.,
“Simultaneous fundus imaging and optical coherence tomography of the mouse retina,”
Investig. Ophthalmol. Vis. Sci., 48
(3), 1283
–1289 https://doi.org/10.1167/iovs.06-0732 IOVSDA 0146-0404
(2007).
Google Scholar
E. Auksorius et al.,
“Multimode fiber as a tool to reduce cross talk in Fourier-domain full-field optical coherence tomography,”
Opt. Lett., 47
(4), 838
–841 https://doi.org/10.1364/OL.449498 OPLEDP 0146-9592
(2022).
Google Scholar
E. Auksorius, D. Borycki and M. Wojtkowski,
“Multimode fiber enables control of spatial coherence in Fourier-domain full-field optical coherence tomography for in vivo corneal imaging,”
Opt. Lett., 46
(6), 1413
–1416 https://doi.org/10.1364/OL.417178 OPLEDP 0146-9592
(2021).
Google Scholar
G. S. Jayabalan et al.,
“Retinal safety evaluation of two-photon laser scanning in rats,”
Biomed. Opt. Express, 10
(7), 3217
–3231 https://doi.org/10.1364/BOE.10.003217 BOEICL 2156-7085
(2019).
Google Scholar
M. T. Pardue, R. A. Stone and P. M. Iuvone,
“Investigating mechanisms of myopia in mice,”
Exp. Eye Res., 114 96
–105 https://doi.org/10.1016/j.exer.2012.12.014 EXERA6 0014-4835
(2013).
Google Scholar
M. Gardner et al.,
“Design considerations for murine retinal imaging using scattering angle resolved optical coherence tomography,”
Appl. Sci., 8
(11), https://doi.org/10.3390/app8112159
(2018).
Google Scholar
V. P. Pandiyan et al.,
“High-speed adaptive optics line-scan OCT for cellular-resolution optoretinography,”
Biomed. Opt. Express, 11
(9), 5274
–5296 https://doi.org/10.1364/BOE.399034 BOEICL 2156-7085
(2020).
Google Scholar
B. Baumann et al.,
“Signal averaging improves signal-to-noise in OCT images: but which approach works best, and when?,”
Biomed. Opt. Express, 10
(11), 5755
–5775 https://doi.org/10.1364/BOE.10.005755 BOEICL 2156-7085
(2019).
Google Scholar
M. A. Herráez et al.,
“Fast two-dimensional phase-unwrapping algorithm based on sorting by reliability following a noncontinuous path,”
Appl. Opt., 41
(35), 7437
–7444 https://doi.org/10.1364/AO.41.007437 APOPAI 0003-6935
(2002).
Google Scholar
M. Kasim,
“Fast 2D phase unwrapping implementation in MATLAB,”
(2017). Google Scholar
D. J. Wahl et al.,
“Adaptive optics in the mouse eye: wavefront sensing based vs. image-guided aberration correction,”
Biomed. Opt. Express, 10
(9), 4757
–4774 https://doi.org/10.1364/BOE.10.004757 BOEICL 2156-7085
(2019).
Google Scholar
K. Liżewski et al.,
“Imaging the retinal and choroidal vasculature using spatio-temporal optical coherence tomography (STOC-T),”
Biocybern. Biomed. Eng., 44
(1), 95
–104 https://doi.org/10.1016/j.bbe.2023.12.002
(2024).
Google Scholar
D. Borycki et al.,
“Multiwavelength laser Doppler holography (MLDH) in spatiotemporal optical coherence tomography (STOC-T),”
Biocybern. Biomed. Eng., 44
(1), 264
–275 https://doi.org/10.1016/j.bbe.2024.03.002
(2024).
Google Scholar
S. A. Burns, A. E. Elsner and T. J. Gast,
“Imaging the retinal vasculature,”
Annu. Rev. Vision Sci., 7 129
–153 https://doi.org/10.1146/annurev-vision-093019-113719
(2021).
Google Scholar
Y. Hwang et al.,
“Retinal blood flow speed quantification at the capillary level using temporal autocorrelation fitting OCTA [Invited],”
Biomed. Opt. Express, 14
(6), 2658
–2677 https://doi.org/10.1364/BOE.488103 BOEICL 2156-7085
(2023).
Google Scholar
A. Joseph, A. Guevara-Torres and J. Schallek,
“Imaging single-cell blood flow in the smallest to largest vessels in the living retina,”
eLife, 8 e45077 https://doi.org/10.7554/eLife.45077
(2019).
Google Scholar
Y. Geng et al.,
“Optical properties of the mouse eye,”
Biomed. Opt. Express, 2
(4), 717
–738 https://doi.org/10.1364/BOE.2.000717 BOEICL 2156-7085
(2011).
Google Scholar
BiographyPiotr Węgrzyn is a PhD student at the University of Warsaw and the International Centre for Translational Eye Research (ICTER). He received his BSc degree in physics, under an individual study program from the University of Warsaw in 2017. He obtained his MSc degree in photonics from Universitat Politecnica de Catalunya in 2018 with a project implemented at ICFO under the supervision of Turgut Durduran. He is member of SPIE, Optica, IEEE Photonics, EPS, and Polish Physical Society. Since 2019, he has been working with Maciej Wojtkowski on combining OCT with ultrafast camera and tunable lasers. In 2021, he co-founded the Candela Foundation. His current research interests include in vivo optical imaging, holography, and optoretinography. Wiktor Kulesza is a PhD student at the Institute of Physical Chemistry and International Centre for Translational Eye Research (ICTER). He received his BSc and MSc degrees in mechatronics with a specialization in photonics engineering from the Warsaw University of Technology in 2020 and 2022, respectively. During his BSc and MSc studies, he participated as an intern and later as a technician in the research done at ICTER, based on which he completed his BSc and MSc theses, under the supervision of Prof. Wojtkowski and Prof. Curatolo, respectively. He is a member of the SPIE, Optica, European Physical Society (EPS), and Polish Physical Society (PTF). His current research interests regard optoretinography, mechanical engineering, optical design, and stereolithography. Maciej Wielgo is a researcher at Warsaw University of Technology (WUT), Warsaw, Poland, and a software developer at XY-Sensing Ltd., and formed part of the IDoc group at The International Centre for Trnaslational Eye Research (ICTER). He holds a MSc in telecommunications engineering. His research interests include synthetic aperture radar (SAR) imaging, compressed sensing, machine learning for noncooperative target recognition, and optical coherence tomography (OCT). He has gained experience in multiple R&D projects developing state-of-the-art experimental radar system demonstrators, prototyping algorithms, and creating image reconstruction software. Sławomir Tomczewski has obtained his MSc and PhD degrees from the Warsaw University of Technology. After finishing his PhD, he gained commercial experience being a software engineer at General Electric Aviation and a holographic system engineer at Envisics LTD. He is currently employed at the International Centre for Translational Eye Research (ICTER), where he is focusing on the development of flicker optoretinography (f-ORG), a method in which OCT is used to measure the retina’s response to stimulation with periodic light pulses. Anna Galińska is a PhD student at the Institute of Physical Chemistry and the International Centre for Translational Eye Research (ICTER). She received her BSc and MSc degrees in biotechnology with a specialization in Chemical Biotechnology—drugs and cosmetics from the Warsaw University of Technology in 2019 and 2021, respectively. Her current research interests focus on creating viral vectors for gene therapies and neuronal electrophysiology. Bartłomiej Bałamut is a PhD student in the ophthalmic biology group at the International Centre for Translational Eye Research (ICTER). His research interests focus on retinal plasticity in regard to structural and functional changes in motion detection. This includes but is not limited to multi-electrodes arrays recording, patch-clamp recordings, viral tracing, and combinations of all the above. Katarzyna Kordecka is a postdoctoral researcher in the Ophthalmic Biology Group at the International Centre for Translational Eye Research (ICTER). She received her PhD at the Nencki Institute of Experimental Biology, Polish Academy of Sciences, Warsaw. During her PhD, she was the principal investigator of a scientific project on the plasticity of the visual system. She is currently pursuing her research interests by investigating the prevention of retinal cell death, the inhibition of pathological functional plasticity, and the restoration of visual signal processing in the diseased retina. In the Ophthalmic Biology Group, she uses her skills in precise in vivo techniques for electrophysiological recording and microinjection into the brain and eye, detection of neuronal specific molecules in microscopic images and data analysis. Onur Cetinkaya is a mechanical engineer with a specialization in optomechanical systems, currently studying MEng in nanotechnology at Dokuz Eylul University in Turkey. Previously he was part of the IDoc and POB groups at the International Centre for Translational Eye Research (ICTER), in Warsaw (Poland), and the Optical+Biomedical Engineering Laboratory (OBEL), at the University of Western Australia, in Perth (Australia). Andrzej Foik specializes in molecular/cell biology, genetics, and electrophysiology, with a strong foundation in data analysis and programming. Starting his research at the Polish Academy of Science, he completed a PhD in neurophysiology at the Nencki Institute. His postdoctoral work at UC Irvine from 2015 to 2020 furthered his expertise, culminating in leading the Ophthalmic Biology Group at ICTER (Warsaw). Robert J. Zawadzki is a professor in the Department of Ophthalmology and Vision Science at the University of California, Davis. His research interests focus on the development of new instrumentation for high-resolution in vivo structural and functional retina imaging (allowing visualization of individual cellular structures). This includes, but is not limited to, optical coherence tomography (OCT), scanning light ophthalmoscopy (SLO), adaptive optics (AO), their combinations, and functional extensions, including optoretinography (ORG). Dawid Borycki received his MSc and PhD degrees in theoretical physics (with honors) from the Nicolaus Copernicus University (NCU) in 2007 and 2011, respectively. During his PhD, he worked as a software engineer at Optopol Technology (Canon group) on Canon’s OCT-HS-100, resulting in several US patents. Post-PhD, he joined the optical biomedical imaging group (at NCU) to develop novel spatio-temporal optical coherence light modulation techniques (STOC-T). From 2014 to 2016, he spent 2.5 years at the University of California Davis, advancing interferometry-based near-infrared spectroscopy for brain tissue imaging. His current research integrates statistical optics, physics, and software engineering to innovate and enhance non-invasive biomedical imaging modalities based on light interferometry and parallel detection. Maciej Wojtkowski is a physicist specialized in applied optics, with seminal contributions in medical and experimental physics. Starting his career at Nicolaus Copernicus University in Toruń (Poland), he is recognized for inventing the first clinical SdOCT for eye imaging, revolutionizing non-invasive eye care globally. Holding over 240 publications and several patents, his work is acclaimed in top journals. Since 2016, he leads the Physical Optics and Biophotonics (POB) research group at the Institute of Physical Chemistry of the Polish Academy of Science. In 2019 he co-founded the International Centre for Translational Eye Research (ICTER), a center of excellence devoted to continuously advancing eye research. Andrea Curatolo is an associate professor in the Department of Physics at Politecnico di Milano, in Milan, Italy. Until recently, he has been the principal investigator and leader of the Image-guided Devices for Ophthalmic Care (IDoc) group at the International Centre for Translational Eye Research (ICTER), in Warsaw (Poland). He is an expert in biomedical imaging, especially in optical coherence tomography (OCT) and derived techniques to enhance diagnostic accuracy and guide surgery, aimed at improved health outcomes, mainly in ophthalmology and oncology. He obtained his PhD in biophotonics at The University of Western Australia. He is also involved in the clinical translation and commercialization of biophotonics technologies; he is listed as an inventor on several patents, and he is engaged in collaborations with MedTech startups. |
Eye
Hemodynamics
Retina
Imaging systems
In vivo imaging
Cameras
Optical coherence tomography