1 April 2010 Optical design for a spatial-spectral volume holographic imaging system
Author Affiliations +
Abstract
The spatial-spectral holographic imaging system (S2-VHIS) is a promising alternative to confocal microscopy due to its capabilities to simultaneously image several sample depths with high resolution. However, the field of view of previously presented S2-VHIS prototypes has been restricted to less than 200 µm. We present experimental results of an improved S2-VHIS design that has a field of view of ~1 mm while maintaining high resolution and dynamic range.
©(2010) Society of Photo-Optical Instrumentation Engineers (SPIE)
Paul J. Gelsinger-Austin, Yuan Luo, Jonathan M. Watson, Raymond K. Kostuk, George Barbastathis, Jennifer K. Barton, and Jose Manuel Castro "Optical design for a spatial-spectral volume holographic imaging system," Optical Engineering 49(4), 043001 (1 April 2010). https://doi.org/10.1117/1.3378025