PurposeWe aim to compare the imaging performance of a cone-beam CT (CBCT) imaging system with noncircular scan protocols (sine-on-sphere) to a conventional circular orbit.ApproachA biplane C-arm system (ARTIS Icono; Siemens Healthineers) capable of circular and noncircular CBCT acquisition was used, with the latter orbit (sine-on-sphere, “Sine Spin”) executing a sinusoidal motion with ±10 deg tilt amplitude over the half-scan orbit. A test phantom was used for the characterization of image uniformity, noise, noise-power spectrum (NPS), spatial resolution [modulation transfer function (MTF) in axial and oblique directions], and cone-beam artifacts. Findings were interpreted using an anthropomorphic head phantom with respect to pertinent tasks in skull base neurosurgery.ResultsThe noncircular scan protocol exhibited several advantages associated with improved 3D sampling—evident in the NPS as filling of the null cone about the fz spatial frequency axis and reduction of cone-beam artifacts. The region of support at the longitudinal extrema was reduced from 16 to ∼12 cm at a radial distance of 6.5 cm. Circular and noncircular orbits exhibited nearly identical image uniformity and quantum noise, demonstrating cupping of −16.7% and overall noise of ∼27 HU. Although both the radially averaged axial MTF (fx,y) and 45 deg oblique MTF (fx,y,z) were ∼20% lower for the noncircular orbit compared with the circular orbit at the default full reconstruction field of view (FOV), there was no difference in spatial resolution for the medium reconstruction FOV (smaller voxel size). Differences in the perceptual image quality for the anthropomorphic phantom reinforced the objective, quantitative findings, including reduced beam-hardening and cone-beam artifacts about structures of interest in the skull base.ConclusionsImage quality differences between circular and noncircular CBCT orbits were quantitatively evaluated on a clinical system in the context of neurosurgery. The primary performance advantage for the noncircular orbit was the improved sampling and elimination of cone-beam artifacts.
To compare the image quality characteristics of a cone-beam CT (CBCT) imaging system with noncircular scan protocols (Sine-on-Sphere) to a conventional circular orbit. A phantom was used to assess image uniformity, image noise, and noise-power spectrum (NPS) for a biplane C-arm (Icono; Siemens Healthineers) that could perform CBCT with either a circular or non-circular orbit (Sine-on-Sphere, “SineSpin”). The non-circular orbit used a sinusoidal motion with an amplitude of ±10º during the orbit. Uniformity and quantum noise were similar for the circular and non-circular orbits. A slight increase in cupping artifact for the noncircular orbit was observed and attributed to slightly increased path lengths (increased scatter-to-primary ratio) for oblique rays through the cylindrical phantom. The NPS clearly depicted closing of the “null cone” about the fz spatial frequency axis owing to improved sampling with the non-circular orbit. A non-circular orbit for CBCT resulted in improved sampling with similar noise magnitude and uniformity compared to a circular orbit.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.