Waveguide grating couplers (WGC) are used for input and output coupling in many planar waveguide
based sensors. By using a chirped grating, guided light can be decoupled and focused to a desired location. The
location and spot size of focused beam depends upon the size and chirp of the grating as well as the wavelength of
the light. The locus of the focused beams for different wavelengths lies along a curve. In many applications a planar
detector array is used to capture spectral data. Wherever the planar detector array does not intersect this focal curve,
images of a point source will be defocused. We develop a theoretical model to calculate the image location and
geometric spot size for a given set of grating parameters.
In order to experimentally verify the model, chirped waveguide grating couplers were fabricated on
HfO2/Quartz planar waveguides using e-beam lithography. The spot size, intensity, and location of diffracted beam
was measured at several wavelengths and compared with the theoretical results.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
We present a miniature tunable Fabry-Perot (FP) filter development effort based on using MEMS technology to
fabricate and package it. The tunable filter development is intended to cover spectral regions from the visible to the
longwave infrared by developing a number of different filters each operating over a different wavelength region.
The main objective of developing such miniature tunable filters is to use each in a miniature hyperspectral imager by
placing it in front of a commercial focal plane array with a suitable optical train. Such a miniature tunable device has
many more applications, i.e., in developing tunable sources. Recently, we succeeded in fabricating some operational
FP filters operating in the visible/near infrared (VIS/NIR) wavelength region from 400 to 800 nm. The filter design
uses one fixed mirror and the second mirror moves using an electrostatic force. The device with a dimension of
18x24 mm2 is composed of two parts: one fixed Ag mirror and one electrostatically moveable Ag mirror.
Commercially available thin quartz wafer with low total thickness variation (TTV) was used as the substrate for
each of these two parts. Au bumps were deposited in both parts in order to control the initial air gap distance and
Au-Au bonding was used to bond two parts together. This paper will describe the device design considerations, the
fabrication process, the effect of electrostatic force, the optical spectral measurements, and present test results.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
We present our results on efficient coupling of Quantum Cascade Lasers (QCLs) into Whispering
Gallery Resonators, Hollow Waveguide. We also present results of micro sensors using the unique
properties of QCLs, e.g. online sensors for Gas Chromatography (GC). We show that because of the
unique brightness properties of QCLs, we could improve GC-Infrared sensors' sensitivity to the same level
as Mass Spectrometry, and with different dimension of chemical information.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
This work presents our recent progress in development of a field-deployable isotopic N2O analyzer based on mid-infrared
cavity ring-down spectroscopy technique. This instrument operates using thermoelectrically cooled technology,
enabling the system to be run unattended for extended periods of time without the use of liquid nitrogen. Ambient
atmospheric gas samples are introduced directly into the instrument which will be capable of measuring N2O
concentration with precision of 0.1 ppb in less than a minute of data acquisition time, while isotopic ratio of 15N/14N of N2O is analyzed at < 1 precision within a few minutes.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Block Engineering has developed an absorption spectroscopy system based on widely tunable Quantum Cascade Lasers
(QCL). The QCL spectrometer rapidly cycles through a user-selected range in the mid-infrared spectrum, between 6 to
12 μm (1667 to 833 cm-1), to detect and identify substances on surfaces based on their absorption characteristics from a standoff distance of up to 2 feet with an eye-safe laser. It can also analyze vapors and liquids in a single device. For
military applications, the QCL spectrometer has demonstrated trace explosive, chemical warfare agent (CWA), and toxic
industrial chemical (TIC) detection and analysis.
The QCL's higher power density enables measurements from diffuse and highly absorbing materials and substrates.
Other advantages over Fourier Transform Infrared (FTIR) spectroscopy include portability, ruggedness, rapid analysis,
and the ability to function from a distance through free space or a fiber optic probe. This paper will discuss the basic
technology behind the system and the empirical data on various safety and security applications.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Tunable Diode Laser Absorption Spectroscopy (TDLAS) is finding ever increasing utility for industrial
process measurement and control. The technique's sensitivity and selectivity benefit continuous
concentration measurement of selected analytes in complex gas mixtures. Tradeoff options among optical
path length, absorption linestrength, linewidth, cross-interferences, and sampling methodology enable
sensor designers to optimize detection for specific applications. This paper describes TDLAS measurement
precision and accuracy limitations in emerging applications that demand increasing volumes of distributed
miniaturized sensors at diminishing costs. In these situations, the TDLAS specificity is a key attribute,
while high sensitivity enables novel sampling package designs with short optical pathlengths. Under these
circumstances, the traditional approaches to optimizing accuracy and precision may fail if analyzer control
features are sacrificed to reduce cost. We describe here a relatively simple TDLAS sensor designed to
meet the needs for acceptable cost, and discuss its theory of operation along with the implications on
measurement accuracy and precision.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Peter C. Kuffner, Kathryn J. Conroy, Toby K. Boyson, Greg Milford, Mohamed A. Mabrok, Abhijit G. Kallapur, Ian R. Petersen, Maria E. Calzada, Thomas G. Spence, et al.
A consortium of researchers at University of New South Wales (UNSW@ADFA), and Loyola University New
Orleans (LU NO), together with Australian government security agencies (e.g., Australian Federal Police), are
working to develop highly sensitive laser-based forensic sensing strategies applicable to characteristic substances
that pose chemical, biological and explosives (CBE) threats. We aim to optimise the potential of these strategies
as high-throughput screening tools to detect prohibited and potentially hazardous substances such as those
associated with explosives, narcotics and bio-agents.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
In this presentation we report on our progress in developing a small, lightweight and low power consumption
carbon monoxide sensor for detection and post-fire cleanup aboard manned spacecraft. The sensor is a laser-based
absorption spectrometer that uses a Quantum Cascade Laser (QCL) operating at 4.61 microns. The target sensitivity for
post-fire cleanup applications is 1 to 500 ppmv. The presentation will detail the laser design and performance and the
bench-top performance of the TDLAS sensor including sensitivity and Allan variance measurements. The status of the
prototype sensor including size, weight and power consumption estimates and measurements will be presented.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Intracavity Laser Absorption Spectroscopy (ICLAS) at IR wavelengths offers an opportunity for spectral sensing with
sufficient sensitivity to detect vapors of low vapor pressure compounds such as explosives. Reported here are key
enabling technologies for this approach, including multi-mode external-cavity quantum cascade lasers and a scanning
Fabry-Perot spectrometer to analyze the laser mode spectrum in the presence of a molecular intracavity absorber.
Reported also is the design of a compact integrated data acquisition and control system. Applications include military
and commercial sensing for threat compounds, chemical gases, biological aerosols, drugs, and banned or invasive plants
or animals, bio-medical breath analysis, and terrestrial or planetary atmosphere science.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Cavity ringdown spectroscopy (CRDS) measures the decay time, of a resonant optical cavity containing a measurand, as
a function of optical frequency. The measurand is identified and quantified by the cavity decay time, which is modified
by the measurand within. As coupling light into a high-finesse optical cavity is difficult, the throughput of the cavity is
small. A recent variant, swept-cavity heterodyne CRDS, interferes backward escaping cavity light, with light reflected
from the cavity input mirror, providing better signal sensitivity due to the heterodyne advantage. The measured
interference signal is demodulated and log-amplified to produce a signal whose slope is representative of the cavity
decay time. This paper, for the first time, examines the conditions required for high-fidelity measurements of the cavity
decay time using swept-cavity heterodyne CRDS and log-amplification technique. We demonstrate that, due to the very
large bandwidth and dynamic range of the log-amplifier, for realistic measurement conditions, the log-amplifier does not
impose any significant restrictions on the measurement accuracy. We also demonstrate, however, the measurement
accuracy is limited by two factors, the detector bandwidth, and segment of acquired data used to measure the slope.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Pathogen detection using Raman spectroscopy is achieved through the use of a sandwich
immunoassay. Antibody-modified magnetic beads are used to capture and concentrate target
analytes in solution and surface-enhanced Raman spectroscopy (SERS) tags are conjugated with
antibodies and act as labels to enable specific detection of biological pathogens. The rapid detection
of biological pathogens is critical to first responders, thus assays to detect E.Coli and Anthrax have
been developed and will be reported. The problems associated with pathogen detection resulting
from the spectral complexity and variability of microorganisms are overcome through the use of
SERS tags, which provide an intense, easily recognizable, and spectrally consistent Raman signal.
The developed E. coli assay has been tested with 5 strains of E. coli and shows a low limit of
detection, on the order of 10 and 100 c.f.u. per assay. Additionally, the SERS assay utilizes
magnetic beads to collect the labeled pathogens into the focal point of the detection laser beam,
making the assay robust to commonly encountered white powder interferants such as flour, baking
powder, and corn starch. The reagents were also found to be stable at room temperature over
extended periods of time with testing conducted over a one year period. Finally, through a
specialized software algorithm, the assays are interfaced to the Raman instrument, StreetLab
Mobile, for rapid-field-deployable biological identification.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Recycling of glass requires the removal of specialist glasses, such as fireproof and mineral glasses, and glass
ceramics, which are regarded as contaminants. The sorting must take place before melting for efficient glass
recycling. Here, we demonstrate the feasibility of a real-time Raman mapping system for detecting and discriminating
a range of industrially relevant glass contaminants in recovered glass streams. The components used are
suitable for industrial conditions and the chemometric model is robust against imaging geometry and excitation
intensity. The proposed approach is a novel alternative to established glass sorting sensors.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Spatially offset Raman spectroscopy (SORS) is demonstrated for the non-contact detection of energetic materials
concealed within non-transparent, diffusely scattering containers. A modified design of an inverse SORS probe has been
developed and tested. The SORS probe has been successfully used for the detection of various energetic substances
inside different types of plastic containers. The tests have been successfully conducted under incandescent and
fluorescent background lights as well as under daylight conditions, using a non-contact working distance of 6 cm. The
interrogation times for the detection of the substances were less than 1 minute in each case, highlighting the suitability of
the device for near real-time detection of concealed hazards in the field. The device has potential applications in forensic
analysis and homeland security investigations.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
SPR based sensing techniques utilize a spectroscopy for transducing biomolecular binding events to variations in
spectra. This label-free and real-time technique has widely applied for conducting biomedical research. In this study, we
present a spectroscopy-based SPR system for monitoring binding between human serum albumin and nucleic acid
library. Compared with conventional SPR technique, this novel system utilizes cost-effective nanostructured arrays and a
portable UV-Vis spectrometer. These advantages enable a promising development of a portable analytical device for
widespread applications. Meanwhile, multispectral analysis used here also helps increase the sensitivity, and thus
transducing the binding event to optical signal efficiently. The result demonstrates that this cost-effective and portable
system could be applied for a future application of selecting target aptamer. Moreover, we also present surface enhanced
Raman spectroscopy (SERS) on the nanostructured arrays in a label-free approach. This integration of multiple
spectroscopy technologies is utilized for conducting genome research efficiently.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Ion mobility spectrometry (IMS) is a well known technique; offering small size and a sensitivity in the ppb range makes
it a typical technique for the detection of explosives or chemical warfare agents. Ordinary IMS devices use in general a
continuously working radioactive ionization source. We use a pulsed non-radioactive electron source for ionization
which offers the innovative possibility of introducing delay times in between ionization and ion detection. The
application and benefits of such a pulsed ionization source in the detection of the chemical warfare agent simulant
dimethyl methylphosphonate (DMMP) and the toxic toluene diisocyanate (TDI) will be demonstrated.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Surface-enhanced Raman spectroscopy (SERS) has repeatedly been shown to be capable of single molecule detection in
laboratory controlled environments. However, superior detection of desired compounds in complex situations requires
optimization of factors in addition to sensitivity. For example, SERS sensors are metals with surface roughness in the
nm scale. This metallic roughness scale may not adsorb the analyte of interest but instead cause a catalytic reaction
unless stabilization is designed into the sensor interface. In addition, the SERS sensor needs to be engineered sensitive
only to the desired analyte(s) or a small subset of analytes; detection of every analyte would saturate the sensor and make
data interpretation untenable. Finally, the SERS sensor has to be a preferable adsorption site in passive sampling
applications, whether vapor or liquid. In this paper, EIC Laboratories will discuss modifications to SERS sensors that
increase the likelihood of detection of the analyte of interest. We will then demonstrate data collected for TATP, a
compound that rapidly decomposes and is undetected on standard silver SERS sensors. With the modified SERS sensor,
ROC curves for room temperature TATP vapor detection, detection of TATP in a non equilibrium vapor environment in
30 s, detection of TATP on a sensor exposed to a ventilation duct, and detection of TATP in the presence of fuel
components were all created and will be presented herein.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
A static dual-channel polarization imaging spectrometer which can simultaneously acquire inphase and antiphase
interference images by using a single CCD camera is presented theoretically. The increase of interference signal together
with the extractions of the pure image and the pure fringes can be achieved from the summation and the difference of the
two interference images respectively. The polarization interferometer is based on the combination of a linear polarizer, a
Savart polariscope and a Wollaston prism. To get straight fringes over a relative large field of view, a combined Savart
polariscope made of the positive and negative uniaxial crystals can be employed. The principle and the configuration of
the system are described.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
We experimentally demonstrate a 300μm long silicon photonic crystal slot waveguide for on-chip near-infrared
absorption spectroscopy. Based on the Beer-Lambert absorption law, our device combines slow light in photonic crystal
waveguide with high electric field intensity in low-index 75nm wide slot, which effectively increases the optical
absorption path length of the analyte. We demonstrate near-infrared absorption spectroscopy of xylene in water,
independent of near-infrared absorption signatures of water, with a hydrophobic PDMS sensing phase that extracts
xylene from water. Xylene concentrations up to 100ppb (parts per billion) (86μg/L) in water were measured.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
We show results on the progress in the development of MOEMS based FT spectrometers dedicated to operate in the mid-IR. Recent research is performed within an EC-FP7 project with the goal to show the feasibility of miniaturized high
performance infrared spectroscopic chemical analyzers. Exploiting the high analyte selectivity of the mid-IR paired with
the inherent sensitivity of an FT-IR spectrometer, such devices could be used in a wide range of applications, from air
monitoring over in-line real-time process control to security monitoring. For practical applicability in these fields,
appropriate detection limits and spectral quality standards have to be met. The presented system aims at a performance to
measure in the range between 4000-700 cm-1 at a spectral resolution better than 10 cm-1, which would clearly outmatch
previous MOEMS based spectrometer approaches. A further technological advantage is the rapid-scan capability. The
MOEMS devices oscillate at 500 Hz. A spectrometer based on this device can acquire 1,000 scans per second in
forward-backward mode. The interplay of all these components with the challenges in system integration will be
described in detail and experimental results will be shown, presenting a significant step forward in smart spectroscopic
sensors, microsystems technology and vibrational spectroscopy instrumentation.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
We report on the development of a portable, battery-operated terahertz spectrometer designed for reflection-mode or
transmission-mode studies of materials in a wide range of applications. We discuss the challenges overcome to achieving
low cost and compact form-factor for the spectrometer instrument, by leveraging commercial fiber-optic packaging
techniques for the lasers and photomixers. This approach also permits the THz source and sensor heads to be located
remotely from the processing and control electronics. We also discuss novel optical THz phase-control and frequency
calibration methods employed in the system.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
At the University of Hawaii, we have developed a compact, portable remote Raman and Laser-Induced Breakdown
Spectroscopy (LIBS) system with a 532 nm pulsed laser for planetary exploration under the Mars Instrument
Development Program. The compact time-resolved remote Raman and LIBS system consists of (i) a regular 85 mm
Nikon (F/1.8) camera lens with clear aperture of 50 mm as collection optics, (ii) a miniature spectrograph that occupies
1/14th the volume of a comparable commercial spectrograph from Kaiser Optical Systems Inc., (iii) a custom mini-ICCD
detector, and (iv) a small frequency-doubled 532 nm Nd:YAG pulsed laser (30 mJ/pulse, 20 Hz) with a 10x beam
expander. In the standoff Raman mode the system is capable of measuring various minerals, water, ices, and
atmospheric gases from a 50 meter range with a 10 s integration time. At shorter distances of 10 m or less, good quality
Raman spectra can be obtained within 1 s. The time-gated system is capable of detecting both the target mineral as well
as the atmospheric gases before the target using their Raman fingerprints. Various materials can easily be identified
through glass, plastic, and water media. The time-gating capability makes the system insensitive to window material,
which is highly desirable for future missions to Venus where instruments are expected to be within the lander. The
standoff LIBS range is 10 m and LIBS spectra of various minerals can be obtained with single laser pulse excitation. The
standoff LIBS capability provides additional elemental verification of the targeted material.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
A novel compact LED array based light induced fluorescence (LIF) sensor has been developed for real-time in-line
monitoring of intrinsic fluorophores in the solid and liquid state. The sensor is essential for on-the-spot, routine, and cost
effective real-time analysis. The sensor is designed to provide real-time emission response along with various smart
sensing parameters to ensure real-time measurement quality that is required for regulated GMP process monitoring
applications. This work describes a LIF sensor tailored for solid-phase fluorometry. Fundamental figures of merit,
excitation overexposure and smart sensing features required for modern process monitoring and control are discussed
within the context of pharmaceutical solid-phase manufacturing and similar applications.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
We present test results from a compact, fast (F/1.4) imaging spectrometer system with a 33° field of view, operating in
the 450-1650 nm wavelength region with an extended response InGaAs detector array. The system incorporates a simple
two-mirror telescope and a steeply concave bilinear groove diffraction grating made with gray scale x-ray lithography
techniques. High degree of spectral and spatial uniformity (97%) is achieved.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
OPTRA is developing a high speed resonant Fourier transform infrared (HSR-FTIR) spectrometer for surface
contaminant measurements via time resolved thermal luminescence. This system incorporates a multipass reciprocating
interferometer and a resonant mirror structure to accomplish the scanning. The resonant scanning approach significantly
reduces the mirror drive power requirement relative to a non-resonant system. Because the spectral range is limited only
by the spectral transmission and reflection properties of the components and the detector responsivity, this system can be
made as broadband as a typical FTIR spectrometer system. For this application, the system will operate over the 700 -
1400 cm-1 spectral range with 8 cm-1 spectral resolution.
This paper presents a portion of the preliminary design of the HSR-FTIR prototype and includes the results from
breadboard tests of the resonant mirror assembly.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Current hyperspectral imagers are either bulky with good performance, or compact with only moderate performance.
This paper presents a new hyperspectral technology which overcomes this drawback, and makes it possible to integrate
extremely compact and high performance push-broom hyperspectral imagers for Unmanned Aerial Vehicles (UAV) and
other demanding applications. Hyperspectral imagers in VIS/NIR, SWIR, MWIR and LWIR spectral ranges have been
implemented. This paper presents the measured performance attributes for a VIS/NIR imager which covers 350 to 1000
nm with spectral resolution of 3 nm. The key innovation is a new imaging spectrograph design which employs both
transmissive and reflective optics in order to achieve high light throughput and large spatial image size in an extremely
compact format. High light throughput is created by numerical aperture of F/2.4 and high diffraction efficiency. Image
distortions are negligible, keystone being <2 um and smile 0.13 nm across the full focal plane image size of 24 mm
(spatially) x 6 m (spectrally). The spectrograph is integrated with an advanced camera which provides 1300 spatial pixels
and image rate of 160 Hz. A higher resolution version with 2000 spatial pixels will produce up to 100 images/s. The
camera achieves, with spectral binning, an outstanding signal-to-noise ratio of 800:1, orders of magnitude higher than
any current compact VIS/NIR imager. The imager weighs only 1.4 kg, including fore optics, imaging spectrograph with
shutter and camera, in a format optimized for installation in small payload compartments and gimbals. In addition to
laboratory characterization, results from a flight test mission are presented.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Two long-wave infrared (LWIR) hyperspectral imagers have been under extensive development. The first one utilizes a
microbolometer focal plane array (FPA) and the second one is based on an Mercury Cadmium Telluride (MCT) FPA.
Both imagers employ a pushbroom imaging spectrograph with a transmission grating and on-axis optics. The main target
has been to develop high performance instruments with good image quality and compact size for various industrial and
remote sensing application requirements. A big challenge in realizing these goals without considerable cooling of the
whole instrument is to control the instrument radiation. The challenge is much bigger in a hyperspectral instrument than
in a broadband camera, because the optical signal from the target is spread spectrally, but the instrument radiation is not
dispersed. Without any suppression, the instrument radiation can overwhelm the radiation from the target even by 1000
times.
The means to handle the instrument radiation in the MCT imager include precise instrument temperature stabilization
(but not cooling), efficient optical background suppression and the use of background-monitoring-on-chip (BMC)
method. This approach has made possible the implementation of a high performance, extremely compact spectral imager
in the 7.7 to 12.4 μm spectral range. The imager performance with 84 spectral bands and 384 spatial pixels has been
experimentally verified and an excellent NESR of 14 mW/(m2srμm) at 10 μm wavelength with a 300 K target has been
achieved. This results in SNR of more than 700.
The LWIR imager based on a microbolometer detector array, first time introduced in 2009, has been upgraded. The
sensitivity of the imager has improved drastically by a factor of 3 and SNR by about 15 %. It provides a rugged
hyperspectral camera for chemical imaging applications in reflection mode in laboratory and industry.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Pharmaceutical counterfeiting is a significant issue in the healthcare community as well as for the pharmaceutical
industry worldwide. The use of counterfeit medicines can result in treatment failure or even death. A rapid
screening technique such as near infrared (NIR) spectroscopy could aid in the search for and identification of
counterfeit drugs. This work presents a comparison of two laboratory NIR imaging systems and the chemometric
analysis of the acquired spectroscopic image data. The first imaging system utilizes a NIR liquid crystal tuneable
filter and is designed for the investigation of stationary objects. The second imaging system utilizes a NIR imaging
spectrograph and is designed for the fast analysis of moving objects on a conveyor belt. Several drugs in form of
tablets and capsules were analyzed. Spectral unmixing techniques were applied to the mixed reflectance spectra
to identify constituent parts of the investigated drugs. The results show that NIR spectroscopic imaging can be
used for contact-less detection and identification of a variety of counterfeit drugs.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. Advances in
instrument portability have made possible the use of FT-IR spectroscopy in emergency response and military field
applications. The samples collected in those harsh environments are rarely pure and typically contain multiple chemical
species in water, sand, or inorganic matrices. In such critical applications, it is also desired that in addition to broad
chemical identification, the user is warned immediately if the sample contains a threat or target class material (i.e.
biological, narcotic, explosive). The next generation HazMatID 360 combines the ruggedized design and functionality
of the current HazMatID with advanced mixture analysis algorithms. The advanced FT-IR instrument allows effective
chemical assessment of samples that may contain one or more interfering materials like water or dirt. The algorithm was
the result of years of cumulative experience based on thousands of real-life spectra sent to our ReachBack spectral
analysis service by customers in the field. The HazMatID 360 combines mixture analysis with threat detection and
chemical hazard classification capabilities to provide, in record time, crucial information to the user. This paper will
provide an overview of the software and algorithm enhancements, in addition to examples of improved performance in
mixture identification.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Fourier transform infrared (FT-IR) spectra of seed and lint cottons were collected to explore the potential for the
discrimination of immature cottons from mature ones and also for the determination of actual cotton maturity. Spectral
features of immature and mature cottons revealed large differences in the 1200-900 cm-1 region, and such spectral
distinctions formed the basis on which to develop simple three-band ratio algorithm for classification analysis. Next, an
additional formula was created to assess the degree of cotton fiber maturity by converting the three-band ratios into an
appropriate FT-IR maturity (MIR) index. Furthermore, the MIR index was compared with parameters derived from
traditional image analysis (IA) and advanced fiber information system (AFIS) measurements. Results indicated strong
correlations (R2 > 0.89) between MIR and MAFIS and between MIR and MIA among either International Cotton Calibration
(ICC) standards or selected cotton maturity references. On the other hand, low correlations between the pairs were
observed among regular cotton fibers, which likely resulted from the heterogeneous distribution of structural, physical,
and chemical characteristics in cotton fibers and subsequent different sampling specimens for individual and independent
measurement.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Peak wavelength and full-width-half-maximum (FWHM) are the two important parameters to characterize the spectra of
monochromatic LED lights. In this work, a low-cost miniature filter-array spectrum sensor for accurate LED
measurement is proposed. For mapping the data from the outputs of the filter-array spectrum sensor to the measurement
parameters of peak wavelength and FWHM, Gaussian curves are used as the basis functions to facilitate the estimation.
In addition, particle swarm optimization (PSO) is utilized for searching the optimal center locations and the widths of the
Gaussian basis functions. The resulting measurement accuracy is competitive to a professional optical spectrometer.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
Spectral imaging measures data that is spatially and spectrally resolved: that is at each point in the image
the spectrum is measured. Classical spectral imaging requires that the sample is scanned either spatially or
spectrally. The main drawback of the classical approaches is that they are sequential. This paper presents a
computed tomographic imaging spectrometer (CTIS) that can image two spatial and one spectral dimension in
one camera frame. Unlike hyper-spectral imaging techniques which provide full spatial and spectral resolution,
with the proposed technique there is a tradeoff between spatial and spectral resolution. The proposed CTIS
system uses two crossed glass gratings that project the spectral and spatial image information to a 2D CCD
camera array. The current system is designed for microscopic applications in pathology and cell imaging as well
as macroscopic material analysis.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.